® hc 3 2016/06 OWNER’S MANUAL
IDATASTART OWNER’S GUIDE 2 WELCOME TO IDATASTART Congratulations on the purchase of your iDataStart HC3 remote start system. Please take a moment to review the following table of contents to help you quickly access the information you need.
IDATASTART OWNER’S GUIDE 3 REMOTE OVERVIEW Your iDataStart HC3 remotes can be programmed in one of three configurations listed below. Please take a moment to familiarize yourself with their general features.
IDATASTART OWNER’S GUIDE 4 REMOTE FUNCTIONS & CONFIRMATIONS Thanks to their multiplexing technology, iDataStart HC3 remotes offer over 30 functions using only 5 buttons. In order to get the most out of your remotes, please take a moment to get acquainted with the following functions: NOTES: 1. 2. 3. 4. 5. 6. 7. 8.
IDATASTART OWNER’S GUIDE BUTTON(S) FUNCTION Engine Start/ Stop* CONFIRMATION (2-WAY ONLY) 5 FUNCTION DESCRIPTION 4 chimes + 4 flashes (Button LEDs will also flash intermittently while engine is running) Start and stops the engine.
IDATASTART OWNER’S GUIDE 6 BUTTON(S) FUNCTION CONFIRMATION (2-WAY ONLY) FUNCTION DESCRIPTION , + Ignition Lock ON/OFF 1 chime ON 2 chimes OFF Automatically locks doors when engine is running. , + Passive Lock & Arm ON/OFF 1 chime ON 2 chimes OFF Automatically locks & arms your vehicle 60 seconds after you unlock it. , + Turbo ON/OFF 1 chime ON 2 chimes OFF Cool down your turbo before turning the engine off. Programmable runtime from 1 to 4 minutes.
IDATASTART OWNER’S GUIDE 7 UPGRADING YOUR FLEX REMOTE CONFIGURATION Want to upgrade the confguration of your iDataStart HC3 remotes? Please take note of the following: 1. A functional iDataStart HC3 system with FLEX 1W or FLEX 2W remote configuration must already be installed in your vehicle. 2. All upgrades must be programmed by an iDataStart Authorized Dealer. Upgrade fees will apply.
IDATASTART OWNER’S GUIDE 8 ADJUSTING ENGINE RUNTIME SETTINGS Once remote started from your factory key fob or long-range remote, your vehicle will run for the programmed ‘runtime’ setting. The default runtime is 15 minutes but it can also be programmed for 3, 5, 10, 25, 30 or 35 minutes. If you wish to change your remote start runtime setting, contact your iDataStart Authorized Dealer.
IDATASTART OWNER’S GUIDE 9 WHEN SERVICING YOUR VEHICLE To ensure safety during vehicle servicing, the remote starter must be placed in ‘Valet Mode’. The ‘Valet Mode’ will disable remote start functionality. To activate or deactivate the ‘Valet Mode’, follow the instructions below or scan the QR codes to view a video tutorial. With Vehicle Key FUNCTION Valet Mode ON Valet Mode OFF ACTION # OF PARKING LIGHT FLASHES 1 Cycle ignition OFF/ON 2x rapidly, then press brake 3x. http://q-r.
IDATASTART OWNER’S GUIDE 10 REMOTE START TROUBLESHOOTING If your iDataStart HC3 remote fails to start the vehicle, the parking lights* will flash three times immediately, then flash a number of times according to the errors below: # OF PARKING LIGHT FLASHES DIAGNOSTIC SOLUTION 3+1 Engine is already running Turn engine OFF 3+2 Key in ignition at ON position Remove key from ignition 3+4 Trunk is open Close trunk 3+5 Foot brake is ON Release foot brake 3+6 Hood is open Close hood 3+8 Tach
IDATASTART OWNER’S GUIDE 11 VEHICLE SHUTDOWN TROUBLESHOOTING If the remote start sequence has been completed and the vehicle shuts down, the vehicle’s parking lights will flash 4 times immediately, then flash a number of times according to the errors below: # OF PARKING LIGHT FLASHES DIAGNOSTIC SOLUTION 4+1 No engine rev detected Turn ignition ON before trying to remote start 4+3 Foot brake detected Release foot brake 4+4 Hood open detected Close hood 4+5 Engine revving over 3000 RPM Check y
IDATASTART OWNER’S GUIDE 12 LIMITED LIFETIME WARRANTY Automotive Data Solutions Inc. (“ADS”) warrants to the original purchaser of the iDataStart product that the following components product shall be free of defects in material and workmanship under normal use and circumstances: Control module and installation harnesses For as long as the original purchaser owns the vehicle in which it was originally installed.
IDATASTART OWNER’S GUIDE 13 FCC STATEMENT 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
IDATASTART OWNER’S GUIDE SAR INFORMATION STATEMENT Your wireless CAR ALARM (TWO WAY) is a radio transmitter and receiver. It is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the U.S. Government. These limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population.
CAR ALARM
Le présentappareilestconforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitationestautorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareildoit accepter tout brouillageradioélectriquesubi, mêmesi le brouillageest susceptible d'encompromettre le fonctionnement. Cetéquipementestconforme aux limitesd'exposition aux rayonnements de la IC définies pour un environnement non contrôlé.
® hc 3 2016/06 CUSTOMER SUPPORT: 866.427.2999 / WWW.IDATASTART.