User manual

ZonePRO™ User Manual
50
Appendix
ZonePRO
In the event that a reset is re q u i red, the ZonePRO offers you the option of perf o r ming a “Hard” or “Soft” Factory Reset.
The results of performing a “Soft” reset are:
• The currently loaded scene is reset to Scene 1. • The state of the current loaded scene parameters is reset to what has
been stored in flash for that scene (this invalidates the state of those parameters when the unit was last turned off).
The result of performing a “Hard” reset are:
A “Soft” reset is performed.• The Node Address for the unit is reset to 32. • The DHCP flag for the unit is reset to 0. •
The IP Address for the unit is reset to 169.254.2.2 • The IP Subnet Address for the unit is reset to 255.255.0.0 The IP
Gateway Address for the unit is reset to 0.0.0.0 The “Fire” state of the unit is reset to UNARMED. The entire User
Flash Memory is erased and initialized to contain the Factory Default Configuration and the Factory Default Scene 1.•
RTC schedule reset (nothing scheduled) and stored to User Flash Memory.
Factory “Soft” Reset From the Front Panel (1260 Only)
Press and Hold <3> button on power-up until the following message appears in the display:
“!:SOFTRESET?”
“Yes<UTIL>”
“No <PAGE1>
To activate a “Soft” Reset: Press the <UTIL> Button.
Pressing any button other than <UTIL> will abort the “Soft” Reset. The unit will reset normally.
Factory “Soft” Reset From ZonePRO Designer (1261 Only)
In the “Help” tab of the program dialog of ZonePRO Designer select 641/1261 Operation > Soft Reset. This sends a mes-
sage to the 1261 to perf o rm a “Soft” Reset and Restart itself. ZonePRO Designer will go offline when the 1261 is re s t a r t e d .
Factory “Hard” Reset From the Front Panel (1260 Only)
Press and Hold <2> button on power-up until the following message appears in the display:
“!: HARD RESET?”
“Yes <UTIL>”
“No <PAGE1>
To activate a “Hard” Reset: Press the <UTIL> Button.
Pressing any button other than <UTIL> will abort the “Hard” Reset. The unit will reset normally.
Factory “Hard” Reset From ZonePRO Designer (1261 Only)
In the “Help” tab of the program dialog of ZonePRO Designer select 641/1261 Operation > Hard Reset. This sends a mes-
sage to the 1261 to perf o rm a “Hard” Reset and Restart itself. ZonePRO Designer will go offline when the 1261 is re s t a r t e d .
Flash Update (1260 Only)
A 1260 firmware release will include a PC application that will download the new version to a unit connected via RS232.
The receiving 1260 should be running. Follow the directions in the PC flasher application.
If, for some reason, you are not able to update your firmware successfully using this method, there is another “back-
door” method. This method forces the 1260 into a special Flash Update Receive Mode:
Hold the <1> button while connecting power to the 1260. The following message will appear:
“WAITING FOR”
“FLASHDOWNLOAD”
blank
“2C000801”
The unit now accepts a flash download from the PC flasher application.
Follow the instructions on the LCD when the flash completes.