User manual
Software Operation
14
Section 3
ZonePRO
™
ZonePRO
™
User Manual
3.3.3 ZC Panel Configuration
The ZC Panel Configuration Page allows setup of wall-mounted Zone Controllers to be used
with the ZonePRO unit.
ID #s - The ID numbers on the left side of the window correspond to the identification num-
ber set using the DIP switches on the individual zone controllers. To select ID#2 for example,
simply flip the 2 switch into the on position. ID 1-6 are connected to one of the ZC inputs on
the rear panel and ID 7-12 are connected to the other input. For ID 7-12 add 6 to the ID #
selected on the back of the ZC. For example, to get an ID# of 10, connect to ZC Input 7-12
and set the ID# to 4.
Types - The zone controllers can be named to eliminate confusion in later menus.
Since several zone controllers have multiple functions examples of each function will be shown:
Scenes - To change scenes a ZC-3 or ZC-4 must be used in the ID #1 position. This zone con-
troller must have the scene check box checked. Select the desired scenes from the list of scenes
on the right hand side of the window and associate it with the selector position A, B, C, D on
a ZC-3 or switch position 1-16 on a ZC-4 (see ZC-4 switch positions within the Appendix).
Fire - The ZC-FIRE is a special case of scene selection. A ZC-FIRE can only be assigned to ID
#2. Select whether the ZC-FIRE should be activated when taken high or low. Select to either
Mute all outputs, or select the desired scene to be loaded.
Name - The zone controller can be named to eliminate confusion in later menus.
Page- If Page steering is desired, a ZC-3, ZC-4 or ZC-7 must be used. To select Page steering,
select the Page box on the ZC-3 and 4, the ZC-7 will come up with the Page box automatically
selected Then select the Paging source from Mic 1, Mic 2, S1 or S2.
Edit- Setting parameters for the Zone Controllers is done by clicking on the Edit button.
Edit - Volume - A ZC-1, ZC-2, ZC-6, or ZC-8 can be used to adjust volume. Select the
desired ZC type, and make sure it has the correct ID number. Set the maximum and min-
imum values for this zone controller. As a default, all volume zone controllers can provide
up to +20dB gain boost and can cut to -Inf to mute.