Specifications

Safety
The standard oering of the CENTERLINE 2100 MCC
provides you with improved safety. CENTERLINE
MCCs are designed to enhance operation and make
it safer. No other MCC manufacturer oers the
same protection for personnel and equipment
• Highlevelofisolationfromhazardousvoltage
• Superiorfaultcontainment
• Solidgroundingsystem
These safety features help protect employees and keep
your process up and running
• AdvanceddiagnosticsfromIntelliCENTERsoftware
provide remote access to data and troubleshooting,
minimizingyourneedtoenterthearcash
boundary zone
• IntelliCENTERsoftwareallowsyoutotroubleshoot
your MCC remotely, without personal protective
equipment (PPE)
• Highdegreeoffaultcontainmenthelpspreventa
single fault from cascading throughout the enclosure,
limiting equipment damage
• Isolation,groundingandremotemonitoringhelp
prevent accidental exposure to energized parts
• Automaticshuttersisolateverticalbuswhena
unit is removed
• Continuousbusbracingprovidesmoreuniform
support than point bracing
• Infraredwindowsallowcompletionofthermal
inspection without opening doors, to minimize
personnel entry in to the enclosure
• Plug-inreplacementunitsallowmaintenancetobe
performed away from energized controls
• Intelligentmotorcontroldeviceswarnofanimpending
failure before it occurs
• NEMAcomponentshelpdeliverdependableoperation
• LockingandInterlockingfeaturesallowforeasier
implementation of your company’s lockout/tagout
safety procedures
• Through-the-doorDeviceNetportgivesyouaccessto
the network without opening the unit door
• Through-the-doorviewingwindowgivesyouvisible
inspection of the disconnect without opening unit door
ArcShield
The CENTERLINE 2100 Motor Control Center (MCC) with
ArcShieldhelpsreducearcashhazardswhileproviding
you with increased protection against internal electrical
arcingfaults.TheCENTERLINE2100MCC,thersttooer
arc resistant features in a low voltage design (up to 600
volts), helps improve personnel safety with a variety of
built-in protective features designed to reduce and
minimizearcashhazards.Arc-containmentlatches
provide an extra level of protection against internal
arcing faults.
The CENTERLINE 2100 MCC with ArcShield meets
Type2accessibilityrequirements(asdenedbyIEEE
C37.20.7-2007 – “IEEE guide for testing metal-enclosed
switchgear rated up to 38kV for internal arcing faults”),
helping to shield your personnel from the eects of
an internal arcing fault on the front, rear and sides
of the enclosure. Pairing ArcShield with IntelliCENTER
technology, you can perform remote monitoring,
congurationandtroubleshootingofyourMCCs,without
enteringthearcashboundaryzone–helpingtofurther
reduceyourexposuretoarcashhazards.
Industry-Leading Motor Control Centers Delivering Safety, Performance And Reliability
CENTERLINE 2100 MCC with ArcShield
6
The safety issue is one of the things that we
are happiest with. The old system created
hazardous troubleshooting conditions,
with technicians having to test and probe
and work around live wires within a
conned panel space.
Ronnie Sexton
Acme Brick – USA