Specifications
Safety
The standard oering of the CENTERLINE 2100 MCC
provides you with improved safety. CENTERLINE
MCCs are designed to enhance operation and make
it safer. No other MCC manufacturer oers the
same protection for personnel and equipment
• Highlevelofisolationfromhazardousvoltage
• Superiorfaultcontainment
• Solidgroundingsystem
These safety features help protect employees and keep
your process up and running
• AdvanceddiagnosticsfromIntelliCENTERsoftware
provide remote access to data and troubleshooting,
minimizingyourneedtoenterthearcash
boundary zone
• IntelliCENTERsoftwareallowsyoutotroubleshoot
your MCC remotely, without personal protective
equipment (PPE)
• Highdegreeoffaultcontainmenthelpspreventa
single fault from cascading throughout the enclosure,
limiting equipment damage
• Isolation,groundingandremotemonitoringhelp
prevent accidental exposure to energized parts
• Automaticshuttersisolateverticalbuswhena
unit is removed
• Continuousbusbracingprovidesmoreuniform
support than point bracing
• Infraredwindowsallowcompletionofthermal
inspection without opening doors, to minimize
personnel entry in to the enclosure
• Plug-inreplacementunitsallowmaintenancetobe
performed away from energized controls
• Intelligentmotorcontroldeviceswarnofanimpending
failure before it occurs
• NEMAcomponentshelpdeliverdependableoperation
• LockingandInterlockingfeaturesallowforeasier
implementation of your company’s lockout/tagout
safety procedures
• Through-the-doorDeviceNetportgivesyouaccessto
the network without opening the unit door
• Through-the-doorviewingwindowgivesyouvisible
inspection of the disconnect without opening unit door
ArcShield
™
The CENTERLINE 2100 Motor Control Center (MCC) with
ArcShieldhelpsreducearcashhazardswhileproviding
you with increased protection against internal electrical
arcingfaults.TheCENTERLINE2100MCC,thersttooer
arc resistant features in a low voltage design (up to 600
volts), helps improve personnel safety with a variety of
built-in protective features designed to reduce and
minimizearcashhazards.Arc-containmentlatches
provide an extra level of protection against internal
arcing faults.
The CENTERLINE 2100 MCC with ArcShield meets
Type2accessibilityrequirements(asdenedbyIEEE
C37.20.7-2007 – “IEEE guide for testing metal-enclosed
switchgear rated up to 38kV for internal arcing faults”),
helping to shield your personnel from the eects of
an internal arcing fault on the front, rear and sides
of the enclosure. Pairing ArcShield with IntelliCENTER
technology, you can perform remote monitoring,
congurationandtroubleshootingofyourMCCs,without
enteringthearcashboundaryzone–helpingtofurther
reduceyourexposuretoarcashhazards.
Industry-Leading Motor Control Centers Delivering Safety, Performance And Reliability
CENTERLINE 2100 MCC with ArcShield
6
“The safety issue is one of the things that we
are happiest with. The old system created
hazardous troubleshooting conditions,
with technicians having to test and probe
and work around live wires within a
conned panel space.”
Ronnie Sexton
Acme Brick – USA