Specifications

52 C4-1280-GigE Camera Hardware Reference Manual Rev. 1.8
Integrated RS232 serial interface and Camera Boot Log
During boot procedure, the camera outputs a log via the integrated RS232 serial interface. The
external C4-I/O-Panel provides a D-sub 9-pin male socket for monitoring the boot log. A null-modem
cable (crosslinked) must be used to connect the C4-I/O-Panel to a host PC. The parameters of the
serial communication are listed as follows:
Baudrate 115200
Data bits 8
Parity None
Stopbits 1
Handshake None
Sample camera boot log
**************************************
MCB InitDone. (WaitClks 75203(84466))
Bootloader(build Mar 6 2012, 08:25:53)
Executing program starting at address: 0x50000000
**************************************
00004700 ms: Camera start.
-------------------------------------------
Start HardwareInit.
Reset sensor to defaults.
Reset sensor.
PLL sensor.
Wait PLL locked. Locked.
StreamAlignLupa done(0x032A).
Current stream delay values.
-24 37 -30 -31 -30 31 -28 29 32 30 -31 -33 -23
-------------------------------------------
Ready to start GEV.
00004743 ms: Start system monitoring.
Stack info: Current Stack position changed to 0x00001F98.
00004752 ms: Load Bootstrap registers.
00004755 ms: **************************************
00004759 ms: Camera type: 1280
00004762 ms: Model: C4_1280_GigE
00004765 ms: MAC: 0-50-C2-8E-D0-74