24 • C4-1280-GigE Camera Hardware Reference Manual Rev. 1.8
The Maximum Intensity Profile Mode (MAX)
In this mode the position of the maximum intensity of laser beam profile is calculated. The result
includes the position value of the maximum (P
MAX
) as well as the maximum intensity value (I
MAX
).
AOI_TRSH
P
MA
X
I
MAX
P
R
The calculation of position value is performed with simple pixel accuracy, i.e. the evaluation of 1024
rows delivers a position range from 0 to 1023 pixels (10 bit). If there is more than one local
maximum, the position of the first detected maximum is output.