Instruction manual
Coal-trol Digital™ - Model TS2 V3
Automation Correct LLC
5/2010 R0
www.automationcorrect.com
Page 12
Instruction Manual
Set
adjustment
handle to
11/16" from
acorn nut
Mechanical
Set Feeder
Screw full
clockwise
Set red nut to
tight against
acorn nut, then
back off 2 turns.
Set red nut
to 5/8" from
acorn nut.
S
N
12:00P
4
adjust
MAX 24
Reading
(Tri-burner)
36
F
N
6
8
Setting
8
Clock
Igniter
Features
Enable
adjust
50
DEG
Display
Keystoker
90/105/
Koker
Alaska
(paddle)
Minimum
Feed Rate
adjust
Reading
(separate
combustion
blower)
99
FF
8
10
30
Convection
Fan
Threshold
F F
adjust
Harman
(Magnum)
Temperature
Units
40
IGN
adjust
MIN
N
8
Maximum
Feed Rate
F
85
8
99
NN N
8CFT
Factory
Value
SETUP Menu Settings and Mechanical Adjustment
This table contains the TS2 thermostat settings as shipped from the factory and typical settings for
various stove models. The "MECHANICAL" setting is adjustment needed for your stove mechanism.
MIN/MAX Adjustment
The Coal-trol Thermostat uses the values set by MIN and MAX as limits to determine the minimum and
maximum fire size allowed on the grate. The factory settings for your stove should be the starting point
for any adjustment. The need for large adjustment from the factory default settings may indicate
mechanical problems with the stove that will not be solved by MIN/MAX adjustment.
While displaying MIN or MAX, the Coal-trol Digital runs the stoker at the MIN or MAX value and NOT
according to desired room temperature. When finished making a MIN or MAX adjustment, press the
MENU button to return to the Round-robin display which resumes normal thermostatic control.
To adjust the
Minimum feed rate go to MIN and observe the fire. Allow the fire to "settle into" its
minimum firing rate. Adjust MIN to the desired fire size. Allow enough time between adjustments for fire
to settle in to a new value. MIN values typically range between 2 and 12, If MIN is set too low, the fire
can go out.
To adjust the
Maximum feed rate go to MAX and observe the fire. Allow the fire to "settle into" its
maximum firing rate. Adjust MAX to the desired fire size. Allow enough time between adjustments for
fire to settle in to a new value. MAX values typically range between 17 and 85. If MAX is set too high
partially burned coal may be driven off the grate into the ash-pan. Coal should be completely burned
about 1 to 2 inches from the end of the grate.
WARNING - The Coal-trol Digital™ is capable of regulating a coal fire smaller than required to
maintain proper chimney draft. Follow all manufacturers recommendations for minimum draft
pressures and temperature. The use of mechanical means such as a draft inducer fan may be
required to ensure proper draft at low fire.
Installation of a carbon monoxide detector (not-
included) is highly recommended.