Installation manual
 Owner Installation Instructions GDO-9 25
PE Beam & Auto-Close
WARNING! Photo electric beams must be installed 
if the closing force at the bottom edge of the door 
exceeds 400N (40kg) force.
Step 19 - Fitting the PE Beams (optional)
Affi x the PE Beams in a strategic location within the 
doorway. We recommend 150mm above the fl oor 
level and as close as possible to the door opening, 
inside the garage. 
Connect the wires from the PE Beam’s wiring 
harness to the terminal block (Fig. 39). The wiring 
diagram is for Model PE-2 (Order Code 90214).
Make sure to align the beams correctly. Follow the 
manual supplied with the PE Beams.
WARNING: When using Auto-Close Mode and PE 
Beams, the doorway must be clear of all obstructions 
and persons at all times. The location of the beams 
and manner in which it is installed might not give 
safety protection at all times. Check to make sure 
that the height of the beam and type used give 
maximum protection possible.
Step 20 - Setting Up Auto-Close Mode
IMPORTANT NOTICE: It is compulsory to have PE 
Beams installed when using Auto-Close mode.
Auto-Close mode is a function that automatically closes 
the door a preset time after the PE Beams recognise that 
a vehicle has left the garage.
The Auto-Close timer only starts after the PE Beam’s 
path is broken the Auto-Close timer has been set. If the 
PE Beam’s path is not broken the door will remain open 
until the path is broken. If the opener incurs a physical 
obstruction (i.e. not from the PE Beams) while closing 
the door, it will re-open and not Auto-Close until the PE 
Beam’s path is broken again.
Step 20.1 - Setting Auto-Close Time
Hold down the AUTO CLOSE TIME button (Fig. 40).
While holding in the AUTO CLOSE TIME button, 
press the PLUS (+) button, - each press will add 
one second to the Auto-Close delay.
To decrease the delay time follow Step 20.1(a)  
and press the MINUS (-) button - each press will 
deduct one second from the Auto-Close delay.
Press the OPERATE button or transmitter to open 
the door. When the door is fully opened the 
OPEN LIMIT LED will fl ash to indicate that Auto-
Close mode is operational. 
Break the PE Beam’s path momentarily to 
initialise Auto-Close. When the door reaches the 
fully opened position, the door will pause for the 
set Auto-Close time and then close.
a.
b.
a.
b.
c.
d.
e.
Accessories
RED
RED
RED
GOLD
PWR
AUX OUT
OSC
GND
PE ( 0 V  )
PE 
BLACK
BLACK
BLACK
BLACK
YELLOW
RED
YELLOW
RED
+
+
-
-
RED
Receiver
Transmitter
Model PE-2
39
fi g
40
fi g