GDO-9 Overhead Garage Door Opener Featuring TrioCode™ Technology Technical Document Installation Manual 1.
WARNING: It is vital for the safety of persons to follow all instructions. Failure to comply with the installation instructions and the safety warnings may result in serious personal injury and/or property damage. Please save these instructions for future reference.
GDO-9 Overhead Garage Door Opener Important Safety Instructions 4 Features 6 Enduro™ Controls 8 Dynamo™ Controls 10 Kit Contents 12 Installation 13 C-Rail Attachment 13 Determine Door Type 14 Mounting - Track Type Door 15 Photo Electric Beam Installation 25 Mounting - Spring Loaded Door 16 Auto-Close Setup 25 Mounting Door Bracket & Arms 17 SmartSolar™ Installation 26 18 Battery Backup installation 27 Programming the Opener Setting Travel Limits - Control Panel 18 Accessori
Important Safety Instructions WARNING: It is vital for the safety of persons to follow all instructions. Failure to comply with the following Safety instructions may result in serious personal injury and/or property damage. CAUTION: If your garage has no pedestrian entrance door, an emergency access device should be installed. This accessory allows manual operation of the garage door from outside in case of power failure.
Important Safety Instructions The unit should be installed so that it is protected from the elements. It should not be exposed to water or rain. It is not to be immersed in water or sprayed directly by a hose or other device. The garage door must be well balanced. Sticking or binding doors must be repaired by a qualified garage door installer prior to installation of the opener. Frequently examine the installation, in particular cables, springs and mountings for signs of wear, damage or imbalance.
Features Thank you for purchasing the Automatic Technology GDO-9 Overhead Garage Door Opener. Designed to suit sectional overhead and one piece tilt up doors, the components and materials used ensure this opener will provide years of smart, simple and secure operation. Listed below are some of the many features: Operation To open or close the door simply press a button on a TrioCode™ handheld transmitter, a wall mounted transmitter, or optional wall switch for two seconds.
SmartSolar™ and Battery Backup Compatibility (optional) The opener can be fitted with a SmartSolar™ or Battery Backup kit for operation in the event of a power outage, or where mains power access is not available. NOTE: If the door is the only entrance to the garage, and a battery backup kit is not fitted, a keyed cable release should be fitted externally to the garage.
Enduro™ Controls 01 24V PWR is used to power devices such as: PE (Input) for photo electric beam for safety and Auto-Close function. » LGT (Input) allow hard wired external trigger for the opener’s courtesy light. » O/S/C INPUT is used for the connection of a wired switch (momentary contact). This switch » can then be used to open, stop or close the door. Install the wall switch in a location where the switch is out of reach of children and the garage door is visible.
17 16 15 01 14 fig 01 02 03 04 05 06 07 08 09 10 11 12 13 Owner Installation Instructions GDO-9 9
Dynamo™ Controls 01 02 24V PWR is used to power devices such as: PE (Input) for photo electric beam for safety and Auto-Close function. » LGT (Input) allow hard wired external trigger for the opener’s courtesy light. » O/S/C INPUT is used for the connection of a wired switch (momentary contact). This switch » can then be used to open, stop or close the door. Install the wall switch in a location where the switch is out of reach of children and the garage door is visible.
17 16 01 15 14 fig 02 02 03 04 05 06 07 08 09 10 11 12 13 Owner Installation Instructions GDO-9 11
Kit Contents Drive Unit 1 x GDO-9 drive unit (Fig. 03) 1 x TrioCode™ Transmitter pack (Fig. 03) (Pack includes two keyring transmitters and batteries) 1 x Wall mount transmitter with battery (Fig. 03) 2 x Door attachment arms (Fig. 03) 1 x Accessory and hardware pack (Fig. 03) 1 x Installation Manual fig 03 PLUS Pre-Assembled Single Piece C-Rail NOTE: The chain or belt in the one piece rail has been tensioned by the factory.
C-Rail Attachment Step 1 - Secure C-Rail to Drive Unit a. b. Locate and insert the shaft of drive unit into the CRail’s sprocket (Fig. 05). Fix the two track brackets with four screws supplied in accessory pack (Fig. 06).
Determine the Door Type Step 2 - Determine Door Type Determine which type of garage door you have as illustrated below. (Fig. 07 to Fig. 09) . For a sectional (panel) door on tracks (Fig. 07) proceed with the installation from Step 3. Track fig 07 Door Sectional door with track Header wall Track For a one-piece door on tracks (Fig. 08) proceed with the installation from Step 3. Door fig 08 Highest point of travel One piece door with track For a one-piece door without tracks (on springs) (Fig.
Mounting on a Track Type Door WARNING: The opener must be securely fastened to structural supports, otherwise opener failure may ensue causing serious personal injury and/or property damage. Level Level Track Track Step 3 - Determine Bracket Position a. b. c. Open the door and find the highest point of travel of the top door panel. Using a level, transfer this height to the wall above the door (Fig. 10) and mark a line 60mm above it. Determine the centre point on the wall above and on top of the door.
Mounting on a Spring Loaded Door WARNING: The opener must be securely fastened to structural supports, otherwise opener failure may ensue causing serious personal injury and/or property damage. Centre of Door Step 7 - Determine the Door’s Centre a. fig 14 b. Find the centre of the door and mark this location both above the door and on top of the door. Draw two lines 21.5mm either side of this (Fig. 14). Step 8 - Prepositioning the Opener a. b. c. Raise the door to open position.
Mounting Door Bracket & Arms Step 11 - Mounting Door Bracket The door bracket comes in two parts. The bottom plate with two mounting holes is used on its own for one piece doors. For sectional doors, the top plate is placed over the bottom plate and is fixed with four (4) screws (Fig. 18). a. b. fig 18 Mount the door bracket, or bracket assembly, on the door’s centre line one-third down the top panel (Fig. 18) using M6 or equivalent screws (not supplied), STEEL DOORS ONLY: Bracket can be welded in place.
Programming The Opener Setting Travel Limits : Via Control Panel Step 13.1 - Setting Travel Limits NOTE: If PE Beams are to be used they must be installed before setting the travel limits. WARNING! Use caution when operating the manual release with the door open since it may fall rapidly due to weak or broken springs, or an improperly balanced door. fig 22 CAUTION! Do not disengage the opener to manual operation with children, persons or any objects including motor vehicles within the doorway. a. b. c. d.
Programming The Opener Setting Travel Limits : Via Transmitter The GDO-9 has the alternate ability to set travel limits using the transmitter, allowing free movement around the garage to better assess the desired limit positions. Step 14.1 - Code a Transmitter for Limit Setting a. b. c. d. Ensure the opener is powered up. Press and hold the DOOR CODE button (Fig. 25). Press Button 1 on the transmitter for two seconds (Fig. 26). Release and pause for two seconds. Press the Button 1 again for two seconds.
Safety Obstruction Forces Safety Obstruction Force Test WARNING! Take care when testing or adjusting the Safety Obstruction Force. Excessive force may cause SERIOUS PERSONAL INJURY and/or PROPERTY DAMAGE. WARNING! Photo electric beams must be installed if the closing force at the bottom edge of the door exceeds 400N (40kg) force. fig 27 Step 15.1 - Testing Close Cycle a. b. c. Press the OPERATE button to open the door (Fig. 27).
Safety Obstruction Forces Adjusting Safety Obstruction Force The Safety Obstruction Force is calculated automatically during setup. Adjusting this is normally only necessitated by environmental conditions such as windy or dusty areas, and areas with extreme temperature changes. WARNING! Photo electric beams must be installed if the closing force at the bottom edge of the door exceeds 400N (40kg) force. fig 29 Step 16.1 - To Increase Force Pressure a. b. c. d. e. Hold down FORCE MARGIN SET button (Fig.
Coding Transmitters Step 17.1 - Code a Transmitter Button for Door Operation a. b. c. d. fig 32 Press and hold the DOOR CODE button (Fig. 32). Press one of the four buttons on the transmitter for two (2) seconds, pause for two (2) seconds, then press the same button again for two (2) seconds. Release the DOOR CODE BUTTON. Press the transmitter button to test. Step 17.
Coding Transmitters Step 17.5 - Coding a Transmitter Button to the Courtesy Light The transmitter can be programmed to operate the courtesy light on the opener independently of the door moving. a. Press and hold LIGHT CODE button (Fig. 36). b. Press one of the four buttons on the transmitter for two (2) seconds, pause for two (2) seconds, then press the same button again for two (2) seconds. c. Release the LIGHT CODE button. d. Press the transmitter button to test.
Coding Transmitters Step 18 - Remotely Coding Transmitters Using this method transmitters can be coded without access to the opener’s control panel as long as a precoded transmitter is available. IMPORTANT NOTE: The door or courtesy light must activate when the steps below are performed. This indicates that the pre-coded transmitter is in range of the opener, and the correct button has been pressed. fig 37 a. b. c. d. e. Take any pre-coded transmitter.
Accessories Receiver Model PE-2 RED RED RED WARNING! Photo electric beams must be installed if the closing force at the bottom edge of the door exceeds 400N (40kg) force. Transmitter GOLD PE Beam & Auto-Close + - + - Step 19 - Fitting the PE Beams (optional) b. fig 39 BLACK BLACK BLACK BLACK YELLOW RED RED RED YELLOW PWR PE PE(0V ) GND OSC AUX OUT Affix the PE Beams in a strategic location within the doorway.
Accessories SmartSolar™ Installation WARNING: Do not connect batteries until Step 21.3 Screws taptite ‘P’ M4x8 Solar charger board Screws taptite ‘S’ M4x8 Step 21.1 - Mount the Charger Board PCB support a. b. Fig 41 c. s w re Sc JP1 Solar Shunt d. e. f. Unplug the drive unit from mains power. Remove the screws, swing open the main cover. Then remove the transformer, EMC board (if fitted) and mains power cable. Mount the PCB support with two screws.
Accessories 4 Wiring diagram 8 6 s& w re sc pen e ov o m r to e e R v co fig 45 Item 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. Description Batteries cover Batteries support Battery 12v sec 12-2.2Agm type Battery coupling wire esv 24 Battery harness Pan head screw w/washer m4x8 Cable clamp acc-1.5(3/16”) SBY-3 version 1.
Final Setup Step 23 - Setting of Courtesy Light Time The preset courtesy light time is three minutes. This time can only be changed by “PG3” programmer. Step 24 - Setting the Pet Mode position The default Pet Mode height can be changed as follows: a. Make sure the door is closed, then press and hold the OPEN button for six (6) seconds (Fig. 46), until you hear three beeps and the OPEN and CLOSE LEDs flash rapidly. b. Press the OPEN button to move the door to the desired Pet Mode open position. c.
Default Settings & Specifications Factory default settings Default Step Maximum Courtesy light time 3 Mins. 4 Mins. Obstruction force margin 2 1 12 Auto close time 0 Secs 1 Sec. 255 Secs. Technical specifications Dynamo™ Enduro™ Power supply 230V - 240V AC 50Hz 230V - 240V AC 50Hz Transformer rating 24V DC 24V DC Standby power 2.2 Watts 2.2 Watts Motor power 100 Watts 100 Watts Motor type 24V DC permanent magnet 24V DC permanent magnet Shuttle travel distance in the C-Rail 2.
Door Status Indicators Door Opener State OPEN LED (Green) Open On Close Opening CLOSE LED (Red) STATUS LED (Yellow) Beeper On Flashing Closing Flashing Door travel stopped Flashing Door obstructed when opening Flashing Door obstructed when closing Flashing Flashing Opener overloaded Alternating flashes Door in open position with AutoClose mode selected One second flashes Pet Mode Engaged On Mains power interrupted Rapid flashes Beeps as door moves Alternating flashes On Service Due
Troubleshooting Guide Symptom Door will not operate Door starts to close but automatically reverses to open position Possible cause Remedy Mains power not switched on Switch on mains power Door is obstructed Remove obstruction Door is locked or motor jammed Unlock door or remove jam Door tracks/hardware damaged Door requires service/repair by qualified technician Adverse weather conditions (wind or cold) causing door to stiffen and become tight in the tracks Increase force margin setting.
Maintenance Maintenance Yearly Whilst your opener does not require any periodic maintenance, the door that it is fitted to, does. Your garage door is a large, heavy, moving object and should be tested regularly to ensure it is in good condition. A poorly maintained door could cause fatal or serious injuries or serious damage to property. Automatic Technology suggests you contact your installer to perform an annual door service.
Enduro™ Parts Listing fig 49 Owner Installation Instructions GDO-9 33
Dynamo™ Parts Listing fig 50 34 GDO-9 Owner Installation Instructions
Warranty and Exclusion of Liability 1. This Warranty is given by Automatic Technology (Australia) Pty Ltd (ABN 11 007 125 368) (ATA), 6-8 Fiveways Boulevard, Keysborough 3173, 1300 133 944, sales@ata-aust.com.au 2. The Competition and Consumer Act 2010 (including the Australian Consumer Law) and other relevant statutes provide a set of statutory consumer guarantees and other legal rights that cannot be excluded, restricted or modified by contract.
© December 2011 Automatic Technology (Australia) Pty Ltd. All rights reserved. TrioCode™, Dynamo™ and Enduro™ are trademarks of Automatic Technology (Australia) Pty Ltd. No part of this document may be reproduced without prior permission. In an ongoing commitment to product quality we reserve the right to change specification without notice. E&OE.