Instruction manual

B&D Doors is a division of B&D Australia Pty Ltd
P: 13 62 63
W: www.bnd.com.au
Specifications
SmartSolarâ„¢V2 Technical Specifications* Garage Door Slider Swing Gate
Load Voltage 24 24 24
Load Continuous Current 3 - 5A 5A 5 - 10A
Number of Cycles per Day 10 10 10
Average Cycle Time (Opening and Closing) 40 seconds 90 seconds 72 seconds
Max. Standby Current
- Without P.E. Beams 100mA 100mA 100mA
- With P.E. Beams 180mA 180mA 180mA
- With 2 x P.E. Beams
260mA
Average total consumption current per day
- Without P.E. Beams
2.75 - 3Ah 3.7Ah 3.4 - 4.4Ah
- With P.E. Beams
4.66 - 4.8Ah 5.55Ah 5.31 - 6.3Ah
- With 2 x P.E. Beams
7.23 - 8.23Ah
Average total consumption current per hour
- Without P.E. Beams
0.11 - 0.13A 0.16A 0.14 - 0.18A
- With P.E. Beams
0.194 - 0.2A 0.23A 0.22 - 0.26A
- With 2 x P.E. Beams
0.3 - 0.343A
Recommended storage battery
capacity / voltage
10.5Ah/24v 12Ah/24V 12 - 18Ah/24V
Wire Gauge and Length from Battery to
Charger board (max)
18AWG, 3m 18AWG, 3m 18AWG, 3m
Solar panel average rated output
generation time per day (winter months)
4 hours 4 hours 4 hours
Solar Panel Output voltage / current 18V / 1.19A 18V / 1.75A 18V / 1.75A