Installation manual
24
GDO-9v2 Enduro™ Owner Installation Instructions
Gen 2
WARNING: It is compulsory to have Safety Beams
installed when using Auto-Close mode. When using
Auto-Close Mode and Safety Beams, the doorway
must be clear of all obstructions and persons at all
times.
Step 20 - Setting Up Auto-Close Mode
Auto-Close mode is a function that automatically closes
the door a preset time after the PE Beams recognise that
a vehicle has left the garage.
The Auto-Close timer only starts after the PE Beam’s
path is broken the Auto-Close timer has been set. If the
PE Beam’s path is not broken the door will remain open
until the path is broken. If the opener incurs a physical
obstruction (i.e. not from the PE Beams) while closing
the door, it will re-open and not Auto-Close until the PE
Beam’s path is broken again.
Step 20.1 - Setting Auto-Close Time
a. Hold down the AUTO CLOSE TIME button.
b. While holding in the AUTO CLOSE TIME button,
press the PLUS (+) button, - each press will add
one second to the Auto-Close delay (Fig. 42).
c. To decrease the delay time follow Step 21.1(a)
and press the MINUS (-) button - each press will
deduct one second from the Auto-Close delay
(Fig. 43).
d. Press the OPERATE button or transmitter to open
the door.
e. Break the Safety Beam’s path momentarily to
initialise Auto-Close. When the door is fully
opened the OPEN LIMIT LED will flash to indicate
that Auto-Close mode is operational.
f. The door will pause for the set Auto-Close time
and then close.
Auto-close Setup
42
fig
43
fig
Wired Safety Beams Installation
Step 19.2 - Safety Beam Failure Emergency Close
When the user finds that they are unable to move the door and suspect that it is due to a faulty SAFETY BEAM
they can attempt to enter Safety Beam Failure Emergency Close mode by press and holding a pre-coded
button on the remote control or OSC button on the console for five seconds.
GDO-9v2GEN2 User Manual v101.indd 24 15/11/2012 10:07:47 AM