Instruction Manual
8
Dominator EasyRoller Instruction Manual
WARNING! A portable power generator
is not recommended due to spikes, surges
and fluctuations in the supply.
85
40
175
135
Minimum Side room Recommended Side room
4.3 Unsuitable Door Types
The drive must not be used with a door incorporating a wicket door, unless
the drive cannot be operated with the wicket door open. The fitting of an
opener to doors with removable mullions is not recommended.
4.4 Sideroom
The minimum sideroom required from the edge of the door curtain is 40mm
to the inside of the door bracket, and 85mm to the wall. If a Battery Backup is
to be fitted, at least 135mm to the bracket is required.
Therefore the recommended sideroom from the edge of the door curtain
is 135mm to the inside of the door bracket, and 175mm to the wall as per
Fig 4.4.1.
4. Setup Requirements
4.2 The Opener:
a. MUST BE installed in a dry position, protected from weather. (Moisture or corrosion not covered by Warranty)
b. Is factory set for RIGHT HAND SIDE installation (from inside garage), but capable of LEFT HAND SIDE installation. Fig 4.2.1
c. REQUIRES properly earthed 3 pin single phase power within an arms length of door and at a suitable height
d. Requires a MINIMUM SIDEROOM of 40mm from the edge of the door to the inside of the door bracket and 85mm to the wall.
e. CAN NOT be installed on a Door Axle Diameter that exceeds 35mm.
LEFT HAND SIDE RIGHT HAND SIDE
40mm
40mm
85mm
85mm
Fig. 4.2.1
Fig. 4.4.1