Instruction Manual

Diamond PD Power Drive : Instruction Manual
Dominator Tempo & Syncro Instruction Manual ATS-3AM & ATS-2AM
17
© Copyright 2019
6.8 Accessories
6.8.1 Terminal Block
Wired accessory items can be connected to the terminal block J4 such as Safety
Beams (Fig. 6.8.1).
Terminal connections from top down are as follows:
1. SB (Safety Beam input, mandatory);
2. GND (Common ground for accessories and Safety Beam);
3. GND (Common ground)
4. OSC (Open/Stop/Close trigger)
Fig.6.8.1
SB
GND
GND
OSC
6.7 Battery Backup
6.7.1 Connecting the Battery Backup
(Available with ATS-3AM model, optional for ATS-2AM)
a. Remove the screw and open the cover to the batteries.
Fig.6.7.1
b. Connect the coupling wire to the battery as shown.
c. Close the cover, securing wirh screw and reconnect power.
NOTE: Batteries may take up to 24 hours to charge fully after initial
installation.
6.7.2 Test the Opener
a. Press either the OPEN or CLOSE button to test the battery backup
installation.
b. Whilst door is in motion, disconnect mains power. The door should
continue to operate as normal.
c. Press either the OPEN or CLOSE button to activate the door. Whilst
door is in motion, reconnect power. The door should complete the cycle
as normal.
6.7.3 LED Battery indicator
WARNING! After Step (b) the opener may become
active (even when power is off). This is a result of a
residual charge in the batteries.
Status Opener Battery LED
Battery not used Stays off
Battery charging
Flashing 1 sec on and 1 sec off
Battery charged
Solid on
Battery in use
Flashing 0.2 sec on and 1.8 sec off
Battery failed
Flashing 0.2 sec on and 0.2 sec off
Fig.6.7.2