User's Manual

Operating controls
Terminal is used to connect Vac to the control board.
10 Amps fuse to protect the electronic circuit board.
This connector is used to connect Battery Charger
SBC02 to the opener.
DC 24V motor connects to this connector.
Operate (blue) Button is used during installation to test
the open, stop and close cycles for the opener. The
opener has to be initialised by the Limit set button before
the Operate Button becomes operable.
Plus (+) Green Button is used during installation to
help set the open limit position. Pressing and holding
this button will move the door in the open direction.
Movement stops when the button is released.
Prog input is used to connect a PG-3 Programmer for
editing functions, diagnostic purposes and accessing
special features.
Open Limit (Green) LED illuminates and ashes when
the door is opening and remains steady on when the
open limit position has been reached.
Force Margin Set The obstruction force pressure is set
automatically by the opener during installation. The
pressure can be adjusted manually using the Force
Margin Set Button. Holding the Force Margin Set Button
and pressing the Plus (+) or Minus (-) Button will increase
or decrease the amount of force. The force margin set
is only ever used if other environmental factors (wind,
etc..) Affect the operations of the door/opener.
Close Limit Red LED illuminates and ashes when the
door is closing and remains steady on when the close
limit position has been reached.
Minus (-) Red Code Set Button is used during installation
to help set the close limit position. Pressing and holding
this button will move the door in the close direction.
Movement stops when the button is released.
Code Set LED light ashes when a code is being stored
or when a transmitter button is pressed.
Limit set Button is used during the installation phase
together with the open and close buttons to set the door
limit positions. The Limit set button is also used to re-
initialise the opener.
Service LED (yellow) indicates when the opener requires
service or repairs.
Courtesy LED Light Module Connectors are used to
connect +24V LED light modules.
Terminal Block (J4):
V+ (+35V/+24V) is used to power Accessories such
as external receiver (200mA max).
EB1 (mandatory) input is used to connect to Safety
Beam.
0V is a 0 volt connection for Safety Beam.
EB2 input is used to connect to Safety Beam.
0V is a 0 volt connection for Safety Beam.
OSC (Operate) is used for the connection of a wired
switch (momentary contact). This switch can then
be used to open, stop or close the door. Install the
wall switch in a location where the switch is out of
reach of children and the garage door is visible.
AUX allows the opener to operate other devices
such as an alarm system.