User's Manual

System Specifications
Factory Default Settings
Default Step Maximum
Maximum motor run time 30 Secs. - -
Courtesy light time 3 Mins. approx. - -
Obstruction force margin 2 1 14
Auto close time 30 Secs - -
Technical Specifications
Input Voltage 120Vac / 60Hz
Fuse (primary) 1.3A (slow blow)
Input power (max) 200 Watts
Standby power, less than 2 Watts
Transformer secondary output Voltage 24Vac
Motor type 24Vdc geared motor with permanent magnet
Shuttle travel distance in the C-Rail 9.19ft (2.8m) approximately (standard)
Maximum shuttle travel distance in the C-Rail 16.4ft (5m) (with extended C-Rail)
Maximum door area 177sq.ft (16.5 m
2
)
Maximum door hanging weight 441lbs (200kg)
Receiver type UHF Multifrequency FM-Receiver
Receiver code storage capacity 14 X 4 button transmitter codes
Transmitter frequency 433.47MHz; 433.92MHz; 434.37MHz
Coding type TrioCode™
Number of code combinations Over 4.29 billion random codes
Code generation Nonlinear encryption algorithm
Remote control battery CR2032 3 Volts
Courtesy light 2 LED Modules
Controller fuse 10A (slow blow)
NOTE: Intermittent operations may occur in areas which experience very strong winds. The strong wind puts extra
pressure on the door and tracks which may in turn trigger the safety obstruction detection system intermittently.
PA1000 Instruction Manual (Instructions d’installation)6