Parameters
Door status indicators
Door opener state Open LED green Close LED red Door status
LED yellow
Beeper
Open On
Close On
Opening Flashing
Closing Flashing
Door travel stopped Flashing Flashing
Door obstructed when opening
Flashing
Door obstructed when closing Flashing Beeps while
door is moving
Opener overloaded Alternating ashes Alternating ashes
Door in open position with auto-
close mode selected
One second ashes
Mains power interrupted Rapid ashes
Button Function
OPERATE Opens/Stops/Closes the door
CODE SET Codes a transmitter button for operate function
FORCE MARGIN SET & PLUS (+) Increases the obstruction force margin setting
FORCE MARGIN SET & MINUS
(-)
Decreases the obstruction force margin setting
FORCE MARGIN SET (then) SET Reloads the factory set default obstruction force margin setting
Press SET (for 6 sec) Clears the door limits set positions. Limits then need to be reset.
SET press and hold until all LEDs
are off
Deletes control parameters excluding transmitter storage memory
DOOR CODE press and hold until
DOOR CODE LED starts ashing
Deletes all transmitter storage memory.
SET & DOOR CODE press and
hold until all LEDs are off
Deletes all control parameters and transmitter storage memory.
Diamond PD Power Drive : Instruction Manual
© Copyright 2011
31PA1000 Instruction Manual (Instructions d’installation)