User's Manual

Default Settings & Specications
Factory default settings
Default Step Minimum Maximum
Courtesy light time 3 minutes Not adjustable ----- ------
Obstruction force margin 0.7A 0.1A 0 2A
Technical specications
Input Voltage 120Vac / 60Hz
Input power (max) 165 Watts
Standby power, less than 1.8 Watts
Transformer secondary output Voltage 24Vac
Motor type 24Vdc geared motor with permanent magnet
Shuttle travel distance in the C-Rail 8.858ft (2.7m) approximately (standard)*
Maximum shuttle travel distance in the C-Rail 12.3ft (3.75m) (with one extension)*
Maximum door area 161.5sq.ft (15m²)
Maximum door hanging weight 385.8lbs (175kg))
Minimum headroom 1” (25.4mm)
Receiver type UHF Multifrequency FM-Receiver
Receiver code storage capacity 8 X 4 button Transmitter Codes
Transmitter frequencies 433.47MHz; 433.92MHz; 434.37MHz
Coding type TrioCode™
Number of code combinations Over 4.29 billion random codes
Code generation Nonlinear encryption algorithm
Transmitter battery CR2032 (3 Volts)
Courtesy light LED’s Module
Controller fuse 10A (slow blow)
*The actual travel distance of the door depends on conguration of the connecting arms.
NOTE: Intermittent operations may occur in areas which experience very strong winds. The strong wind puts extra pressure
on the door and tracks which may in turn intermittently trigger the safety obstruction detection system.
PA800V1 Instruction Manual (Instructions d’installation)6