User's Manual
Operating Controls
Terminal Block (J2):
V+ (+35V/+24V) is used to power Accessories such as external receiver (200mA max)
SB-1 (mandatory) input is used to connect to Safety Beam
0V is a 0 volt connection for Safety Beam
SB-2 input is used to connect to Safety Beam
0V is a 0 volt connection for Safety Beam
AUX/OSC This output has two chosen functions:
AUX
allows the operator to operate other devices such as an alarm system.
OSC
is used for the connection of a wired switch (momentary contact). This switch can then be used to open, stop
or close the door. Install the wall switch in a location where the switch is out of reach of children and the garage door
is visible.
CODING LED (Red) light ashes when a code is being stored or when a transmitter button is pressed.
DOOR CODE button is used for storing or erasing transmitter buttons for door operation
SERVICE LED (Yellow) indicates when the opener requires service or repairs.
SET button (Orange) is used during the installation phase together with the Open and MINUS (-) buttons to set the door
limit positions. The Set button is also used to re-initialize the Opener.
OPERATE button (Yellow) is used during installation to test the open, stop and close cycles for the opener. The opener
has to be initialised by the SET button to make the OPERATE button operable.
FORCE MARGIN SET button: The obstruction force margin is set automatically during installation. The margin can be
adjusted manually using the Force Margin Set button (White). Holding the Force Margin Set button and pressing PLUS
(+) or MINUS (-) buttons will increase or decrease the amount of force. The Force Margin Set should only be used if
environmental factors (wind, etc.) affect the operation of the door.
OPEN LIMIT LED (Green) the LED is very helpful during installation. It illuminates and ashes when the door is opening
and remains steady on when the open limit position has been reached.
PLUS (+) button (Green) is used during installation to help set the open limit position. Pressing and holding this button
will move the door in the open direction, releasing stops the door.
NOTE: The safety obstruction detection is inoperable when the PLUS (+) button is used to move door.
CLOSE LIMIT LED (Red) the LED is very helpful during installation. It illuminates and ashes when the door is closing
and remains steady on when the close limit position has been reached.
MINUS (-) button (Red) is used during installation to help set the close limit position. Pressing and holding this button
will move the door in the close direction. Movement stops when the button is released.
NOTE: The safety obstruction detection is inoperable when the CLOSE button is used to move door.
DATUM ADJUST SCREW is used during limits set up to indicate the mid point of the door’s travel.
10A FUSE (Slow Blow)
PROG INPUT is used to connect the handheld “PG-3” Programmer for editing control and receiver functions, accessing
diagnostic tools, and activating special features and operating modes.
JP1 SOLAR CONNECTOR the shunt must be tted for solar operation.
COURTESY LIGHT The LEDs Module is used for the courtesy light.
01.
02.
03.
04.
05.
06.
07.
08.
09.
10.
11.
12.
13.
14.
15.
16.
PA700V1 Instruction Manual (Instructions d’installation)8