User's Manual
Track
Level
Door
Drilled holes
Structural member
Fig.10
Fig.9
Fig.8
Fig.7
Mounting Operator for Track Type Door
Step 3 - Determine Bracket Position
Open the door and nd the highest point of travel of a.
the top door panel.
Using a level, transfer this height to the wall above the b.
door (Fig.7) and mark a line 2.36” (60mm) above it.
Determine the centre point on the wall above and c.
on top of the door. Then draw two lines extending
21.5mm from each side of the centre point. (Fig.8)
Step 4 - Mounting the Wall Bracket
Centre the bracket over the intersection of these two a.
lines. Mark centres for at least two holes (Fig.8).
Ensure a solid mounting point is behind these •
holes.
Drill holes into the wall with an appropriate sized bit.b.
Secure bracket to the wall using: c.
IF CONCRETE OR BRICK - 8mm or 5/6 loxins or
dynabolts.
IF TIMBER - wood screw #20 or equivalent
(minimum 50mm long).
Step 5 - Attach the C-Rail to the Wall Bracket
Attach the C-Rail assembly to the wall bracket with the a.
90mm long clevis pin and secure with the supplied
snap pin (Fig.9).
Leave the powerhead in its packing box for protection b.
during installation.
Step 6 - Securing the Powerhead to the Ceiling
Raise the powerhead from the packing box and a.
support it in the horizontal position with a step ladder.
Open the garage door. Rest the opener on the open b.
door and use a scrap piece of wood to bring it to
horizontal level.
Line up the track perpendicular to the wall.c.
Secure the perforated angle (not supplied) to the d.
ceiling above where the powerhead’s mounting holes
will be once fully installed. A representative mounting
is shown (Fig.10).
Connect the powerhead to the ceiling mounted e.
perforated angle with M8x20mm screws and nuts.
Strips should not extend more than 0.71” (18mm )
below the centre of the powerhead mounting holes
(Fig.10).
WARNING: The opener must be securely
fastened to structural supports, otherwise
opener failure may ensue causing serious
personal injury and/or property damage.
WARNING: Make sure concrete, brick wall
or timber lintels are solid and sound so as to
form a secure mounting platform.
43
21.5
21.5
PA700V1 Instruction Manual (Instructions d’installation)12