Troubleshooting guide

Owner Installation Instructions GDO-9v2 SecuraLift
®
27
Default Settings & Specifications
-- 3 minCourtesy light time
111
0 secAuto close time
4 min
1 sec
Technical specifications
230-240V AC, 50HzMains
2.2 Wattsrewop ybdnatS
150 WattsRated input power
tengam tnenamrep CD V42epyt rotoM
Shuttle travel distance in the C-Rail 2.8m approx (standard)
Maximum shuttle travel distance in the C-Rail 5m (with extended C-Rail)
Maximum door size
Maximum door weight
16.5m
2
(5500mm (Width) x 3000mm (Height))
225 kg
Minimum Clearance
(Bottom of C-Rail to highest point of door travel)
25mm
)gk08( N008ecrof kaep mret trohS
450N (45kg)Rated lift force: Chain / Timing Belt
4 minRated operating time
14 x 4 button Transmitter Codesyticapac egarots edoc revieceR
Transmitter/Receiver type
Multi-frequency Code Hoppingepyt gnidoC
sedoc modnar noillib 92.4 revOsnoitanibmoc edoc fo rebmuN
mhtirogla noitpyrcne raenil-noNnoitareneg edoC
CR2032 (3V)yrettab rettimsnarT
LEDs (Light Emitting Diodes)thgil ysetruoC
wolb wols A01esuf rellortnoC
NOTE: Intermittent operations may occur in areas which experience very strong winds. The strong wind puts
extra pressure on the door and tracks which may in turn trigger the safety obstruction detection system
intermittently.
UHF Multi-frequemcy FM
Obstruction force margin
2
Factory Default Settings
Default Step Maximum
Recommended force for manual operation
(excessive force)
No greater than 150N (15kg)