Installation manual
18
GDO-8V2 EasyRoller® II Owner Installation Instructions
Parameters
Door Status Indicators
Door Opener State Open LED
Green
Close LED
Red
Door Status
LED yellow
Beeper
Open On
Close On
Opening Flashing
Closing Flashing
Door travel stopped Flashing
Door obstructed when
opening
Flashing
Door obstructed when closed Flashing Beeps
while door
is moving
Opener overloaded Alternating fl ashes Alternating fl ashes
Mains power interupted Rapid fl ashes
Buttons Function
Operate Opens/Stops/Closes the door
Door code Codes a transmitter button for OPERATE function
Force Margin Set + plus (+) Increases the obstruction force margin setting
Force Margin Set + Minus (-) Decreases the obstruction force margin setting
Force Margin Set (then) Set Reloads the factory set default obstruction force
margin setting
Close for 6 seconds Clears the door limits set positions. Limits then need
to be reset
Set (then power on) & hold until all LEDs are off Deletes control parameters excluding transmitter
storage memory
Door Code (then power on) & hold until all LEDs
are off
Deletes all transmitter stored in memory.
Set for 2 seconds Re-initialises the Opener to re-calculate force margins
Purchased from: Phone:
Installed by: Date:
Serial No: