Factory Default Settings
Default Step Maximum
- - 4 minemit thgil ysetruoC
26
12nigram ecrof noitcurtsbO
4 min 1 0 secAuto-close time
Technical Specifications
2.2 WattsStandby power
550 WattsRated input power
250 Watts (1/3 HP)Motor rating
Alternating CurrentMotor type
* 2.7m approx. (Standard)Shuttle travel distance
Maximum shuttle travel distance in the C-Rail
Maximum door size
Maximum door weight
16.5m (5500mm (Width) x 3000mm (Height))
2
225kg
700N (70kg)Short-term peak force
500N (50kg)Rated lift force
No greater than 150N (15kg)Recommended force for manual operation
(excessive force)
2 min in 30 minRated operating time
14 x 4 button Transmitter CodesReceiver code storage capacity
UHF Multi-frequency FMTransmitter/Receiver type
Multi-frequency Code HoppingCoding type
Over 4.29 Billion random codes Number of code combinations
ro( ecivres hguor W06 V042 )tnuom wercs( nosidEthgil ysetruoC
construction type)
wolb wols A5esuf rellortnoC
NOTE:
1. The door must be well balanced. A person should be able to lift the door up manually with very little effort in
case of an emergency.
2. Intermittent operations may occur in areas which experience very strong winds. Strong wind puts extra pressure
on the door and tracks which may in turn trigger the safety obstruction detection system intermittently.
Default Settings & Specifi cations
Code generation Non-linear encryption algorithm
Transmitter battery
CR2032 (3V)
230-240V AC, 50HzMains
* 3.750m (with extension)