Installation manual

Owner Installation Instructions GDO-10V1 Toro
®
39
Step 16 - Setting Up Auto-Close Mode
IMPORTANT NOTICE: the Auto-Close function is not available unless PE Beams are installed.
Auto-close mode is a function that automatically closes the door a preset time after the PE Beams recognise
that a vehicle has left the garage.
The Auto-close timer only starts after the PE Beams path is broken the Auto-close timer has been set. If the
PE Beams path is not broken the door will remain open until the path is broken. If the opener incurs a physical
obstruction (i.e. not from the PE Beams) while closing the door will re-open and not Auto-close until the PE
Beams path is broken again.
Menu 3. Auto-Close Times
The auto-close modes automatically closes the door after it has been operated. To implement this, the
controller starts a timer once the door has reached its desired open position. The timer then counts down and
when it expires the controller starts to close the door. Details of the four auto-close modes are outlined below.
Standard Auto-Close
This mode is selected by entering a non-zero time for the STD Auto-close parameter. When selected the
door will auto-close after being fully opened (except when the door has reversed to the open position after
a motor obstruction or overload unless A/C after open and/or close Obstruction are selected). Countdown is
suspended by: P.E., OPN or SWP input being active. The countdown is aborted if the STP input is activated. If
the door is already open and the OPN or the SWP input is activated then the countdown will start.
PE Beams Triggered Auto-Close
This mode is selected by entering a non-zero time for the “PE Beams Auto-close” parameter. This mode is
used to auto-close the door but only after a vehicle have passed through the doorway and triggered the PE
Beams input. The swipe input can be used to clear the P.E triggered status so that the PE Beams input must
be activated again before the countdown will start. As with the other PE Beams modes the STP input will abort
countdown and the OPN and SWP inputs will restart the countdown if the door is OPEN.
Pedestrian Access Auto-Close
This mode is selected by entering a non-zero time for the “Ped’n A/C” parameter. When selected, the door will
auto-close after being opened for pedestrian access unless it was following a reverse from an obstruction.
PE Beams triggered pedestrian auto-close
This mode is selected by entering a non-zero time for the “P.E. Ped’n A/C” parameter. This mode is the
same as the PE Beams triggered auto-close mode but it only operates during pedestrian access. As the
SWP input is not available during pedestrian access, the PED input can be confi gured to act in a SWP
mode by setting the “PED I/P = PED SWIPE MODE” parameter to ON.
Auto-Close After Obstruction
Three parameters are provided to enable the auto-close feature to be activated after obstructions and power
up. Normally the auto-close feature is not enabled after obstructions for safety reasons. P.E beams must be
used for these features to be activated.
Auto-close mode