Installation manual
Owner Installation Instructions GDO-10V1 Toro
®
37
Step 14.1 Fitting Solenoid Or Magnetic
Locks
Install the lock mechanism on the door as per the
manufacturers instructions. See (Fig. 61) for the wiring
diagram .
Menu 4. Lock Times
Lock output can be programmed for both hold
and pulse mode. The operation of the lock can be
programmed to activate prior to the door behave
differently on open cycle to that on close cycles.
Press NEXT or PREV on the wall control unit to
navigate to the Menu 4 Lock Times.
Press SET to select the sub menu.
Press NEXT or PREV to navigate through the sub
menu.
Press OPEN to increase or CLOSE to decrease
value
Press SET to save the new value.
Press STOP button two times to exit and test the
locks operation.
1.
2.
3.
4.
5.
6.
61
fi g
Accessories Installation
LIGHT
LOCK
LOCK
NO
NC
COM
NO
NC
COM
SUITABLE
POWER
SUPPLY
Parameter Min Max Default Step Unit Menu No.
OPEN LOCK TIME Set the time the lock is
activated for on open cycles
0.0 Hold 0.0 0.1 Sec 4
CLOSE LOCK TIME Set the time the lock is
activated for on close cycles
0.0 Hold 0.0 0.1 Sec 4
PRE-OPEN LOCK TIME
Time the lock is activated for prior to opening
0.0 25.5 0.0 0.1 Sec 4
PRE-CLOSE LOCK TIME
Time the lock is activated for prior to closing
0.0 25.5 0.0 0.1 Sec 4