Installation manual
30
GDO-10V1 Toro
®
Owner Installation Instructions
Parameter Min Max Default Step Unit Menu No.
OPEN SPEED VOLTAGE
Sets the full speed motor voltage
~12.0 ~24 ~22 ~1 Volts 6
CLOSE SPEED VOLTAGE
Sets the full speed motor voltage
~12.0 ~24 ~20 ~1 Volts 6
The opener’s standard operation can be altered by editing various parameters. This section describes
the parameters and the effect they have. Use the VIEWING AND EDITING PARAMETER PROCEDURE on
Page 15 to make changes.
Menu 6. Motor Settings
Motor speed
The maximum speed the motors run at is controlled by the OPEN AND CLOSE SPEED VOLTAGE parameter.
The default value is the maximum recommended for normal operation. If however the door move too quickly
for a particular installation the voltage can be reduced to make the motors run slower. NOTE: Altering these
parameters will cause the travel limits to be cleared.
Control Board Adjustments
Menu 7. Operating Modes
7.1 Safety Close Mode
By enabling this parameter it allows the user to close the door only by holding the close button on the wall control unit
or by holding the CLS input active. The door can not be closed by Auto-close or by Transmitters.
if the pe beams are not installed the controller will be loaded with safety close mode and A Message
ATTENTION! “SAFETY CLOSE MODE has been enabled as no P.E beam has been
installed! This means that the door can only be closed by HOLDING the ‘CLS input’
or ‘CLOSE button’. All other means of closing the door are disabled. Press SET to
continue. “ will be displayed. Press set button to continue.
7.2 PE Beams Input Response Mode
The PE Beams input can be confi gured to respond in one of three modes.
Reverses close cycles
In this mode the PE Beams input has no effect when opening but will cause the door to reverse if activated
when closing.
Close cycles stop
In this mode the PE Beams input has no effect when opening but will stop the door when closing.
Open and close cycles stop
In this mode all cycles are prevented from being completed or initiated when the PE Beams input is active.
7.3 Pe Beams Obstruction Reverse Time Mode
Normally after PE Beams obstruction the door will fully open to its open position. After PE Beams close
obstruction the doors open cycle can be reduced from 5 sec to its full open position.
7.4 General Purpose Input (GPI)
GPI input can be confi gured as osc ,ped or day light saving setup . Activated by GPI input terminal with N/O
switch.
When GPI Selected As OSC :
If the door is moving the activation of GPI input or by transmitter button with OSC function assigned will