Pedestrian Access Position
After completing the limit setup procedure the
Pedestrian access position is automatically set to a
position which is in the middle of the door travel. The
position can be manually set by following the SETTING
PEDESTRIAN POSITION procedure.
NOTE: Before setting the pedestrian access position
the door must be in the fully closed position.
Step 12.1 Navigating To “Set pedestrian
Menu”
1. Press PREV to navigate to the Menu 11.
2. Press SET - MENU 11.1 is displayed.
3. Press NEXT to go to MENU 11.3
4. Press SET two times to enter Set Pedestrian
procedure (Fig. 46).
Step 12.2 Setting pedestrian position
1. Press OPEN button on the wall control unit or button 1
on the transmitter to move door to desired pedestrian
access position (Fig. 47).
2. Press SET button on the wall control unit or button 2
on the transmitter to record position .
3. Press STOP button to exit to main screen
Step 12.3 Checking Pedestrian Position
When activated by a transmitter button which is coded
as Ped mode, drives the door to the preset position
from either above or below. Ped Mode’s active status
is indicated on the display (Fig. 48) . If a Ped Mode
button is pressed while the door is moving the door will
stop. If a Ped Mode button is pressed when the door is
in the Ped position, then the door will close.
Errors During Setting Of Travel Limits And
Pedestrian Position.
During the above procedure many error checks are
preformed. If an error is detected a message will be
displayed indicating the error.
Setting Pedestrian Position Menu11
MENU 11.3
Set Pedestrian
PR E S S
46
g
48
g
To Pedestrian
Position,
SET
OR
PR E S S
PR E S S
PR E S S
Ped’n Access
FRI 11:06:44 STD
47
g