Installation manual

18
GDO-10V1 Toro
®
Owner Installation Instructions
Setting Limits: Via Transmitter
15
g
The GDO-10v1 has the alternate ability to set travel
limits using the transmitter, allowing free movement
around the garage to better assess the desired limit
positions. In order to use a transmitter it must fi rst have
at least one of its buttons coded to the door controller.
The function assigned to the transmitter’s buttons is of
no concern here as the buttons are temporally assigned
to OPEN, CLOSE and SET (Fig. 16).
Step 7. Code A Transmitter For Limit Setting
Step 7.1. Navigating to “code transmitter”
menu
1. Press NEXT to navigate to the Menu 1
2. Press SET to enter code set procedure (Fig. 15).
Step 7.2. Storing Transmitter Code
1. Controller will prompt to press one of the
transmitter’s button.
2. Press the transmitter button you wish to use to
operate the door Opener (e.g. button 1) .
3. Press same transmitter button again as prompted by
display.
4. Press set button to store the transmitter.
Step 7.3 Navigating To “Set Door Travel
Menu”
1. Press PREV to navigate to the Menu 11.
2. Press SET to display MENU 11.1.
3. Press SET two times to enter the limit setting
procedure. The close blue led will start to fl ash
Setting Limits Via Transmitter
Press and hold Button 4 on the transmitter to close
the door.
If the door opens, release the button 4 and
press the stop button once on the wall control
unit to change the motor’s direction, then Press
and hold Button 4 on the transmitter to close
the door.
If the door is closed too far, press Button 1 to
“inch” the door towards open.
When happy with the close limit position, press
Button 2 to store this in memory. The open green
led will starts to fl ash.
Press Button 1 to open the door.
If the door is opened too far, press Button 4 to
“inch” the door towards close
IMPORTANT WARNING: The door will
automatically close and open once next step is
performed. Ensure that no persons or objects are
in the door’s path.
When happy with the open limit position, press Button 2
on the transmitter to store into memory.
The door will now automatically close and open to calculate
the safety obstruction settings. After this, If PE Beams are
installed then the opener can be operated with the OPEN or
CLOSE button on the wall control unit or from the transmitter
else controller will be loaded with “Safety Close Mode” see
page 30.
»
»
»
Button 1
(Inch Open)
Button 4
(Inch Close)
Button 2
(Set)
MENU 1
Code Transmitter
PR E S S
16
g