6.8 Accessories
Fig.6.8.1
6.7 Battery Backup
Fig.6.7.1
WARNING! After Step (c) the opener may become
active (even when power is off). This is a result of a
residual charge in the batteries.
AVERTISSEMENT!
Après l’étape (b) l’opérateur
peut deviendra actif (même alimentation est
éteinte). Ceci est un résultat d’une charge résiduel
dans les batteries.
6.7.1 Connecting the Battery Backup
(Optional with ATS-3AM & ATS-2AM models)
a. Remove the screw and open the cover to the batteries. (Fig.6.7.1)
b. Connect the coupling blue harness
2A
to the red plus terminal
A+
on
Battery
A
, then connect coupling blue harness
2B
to the black minus
terminal
B-
on Battery
B
.
c. Connect the coupling black wire
4A
to the black minus terminal
A-
on
Battery
A
, then connect coupling red wire
4B
to the red plus terminal
B+
on Battery
B
.
d. Close the cover, securing with screw and reconnect power.
NOTE: Batteries may take up to 24 hours to charge fully after initial
installation.
6.7.2 Test the Opener
a. Press either the OPEN or CLOSE button to test the battery backup
installation.
b. Whilst door is in motion, disconnect mains power. The door should
continue to operate as normal.
c. Press either the OPEN or CLOSE button to activate the door. Whilst
door is in motion, reconnect power. The door should complete the cycle
as normal.
Battery LED Battery Status
OFF Not Fitted / Not used
ON
Charged
Blink every 2 sec
In use
Flashing
Charging
Rapid Flashing
Battery Fault
2A
A
B
2B
A+
B-
4A
4B
A-
B+
6.8.1 Terminal Block
Wired accessory items can be connected to the terminal block J4.
Terminal connections from top down are as follows (Fig. 6.8.1):
a. +35V (Auxillary)
b. AUX (Auxillary)
c. SB (Safety Beam input, mandatory);
d. GND (Common ground for accessories and Safety Beam);
e. GND (Common ground)
f. OSC (Open/Stop/Close trigger)
Refer to Appendix B for how to adjust parameters.
6.8.2 Connecting or Disconnecting Accessories
When disconnecting or reconnecting accessory base station modules (Wireless PE Beams)
press the MODE button on the opener repetitively until the GEAR LED is on, then press
the STOP / SET button until the main courtesy light stops flashing.
NOTE: If an Auto-lock is installed ensure that the channels on the transceivers on each
device are different. The channel on the transceiver can be changed by sliding the switch
in either direction