Default Settings & Specifi cations
Factory default settings
Default Step Maximum
Maximum motor run time 25 Secs. - -
Courtesy light time 3 Mins. 10 Secs. 4 Mins.
Obstruction force margin 8 1 20
Auto close time 0 Secs 1 Sec. 4 Mins.
Technical specifi cations
Power supply 230V - 240V AC 50Hz
Transformer rating 24V DC
Standby power 2.2 Watts
Motor power 100 Watts
Motor type 24V DC permanent magnet
Shuttle travel distance in the C-Rail 2.8m approx (standard)
Maximum shuttle travel distance in the C-Rail 5m (with extended C-Rail)
Maximum door opening: Width:
Height:
Weight:
5500mm (16.5m
2
)
3000mm
100 kg
Minimum Clearance
(Bottom of C-Rail to highest point of door travel)
25mm
Short term peak force 800N (80kg)
Lift force 500N (50kg)
Nominal force 150N (15kg)
Receiver type UHF 433.92 MHz AM Receiver
Receiver code storage capacity 24 x 4 button transmitter codes
Transmitter frequency ~= to 433.92 MHz
Coding type Multi-frequency Code hopping
Number of code combinations Over 4.29 billion random codes
Code generation Non-linear encryption algorithm
Transmitter battery A23 Alkaline 12 Volts
Courtesy light Festoon style lamp
Controller fuse 10A slow blow
NOTE: Intermittent operations may occur in areas which experience very strong winds. The strong wind
puts extra pressure on the door and tracks which may in turn trigger the safety obstruction detection system