Troubleshooting guide

30
GDO-11v1 SecuraLift
®
Owner Installation Instructions
Parameters
Door Status Indicators
Door Opener State OPEN LED (Green) CLOSE LED (Red) Beeper
Open On
Close On
Opening Flashing
Closing Flashing
Door travel stopped Flashing Flashing
Door obstructed when opening Flashing
Door obstructed when closing Flashing Beeps as door moves
Opener overloaded Alternating fl ashes Alternating fl ashes
Pet Mode Engaged On On
Mains power interrupted Rapid fl ashes
Button Functions
Buttons Function
OPERATE Opens/Stops/Closes the door
DOOR CODE Codes a transmitter button for operate function,
Vacation function, Auxilary function, Pet mode and
Light function
FORCE MARGIN SET & OPEN Increases the obstruction force margin setting
FORCE MARGIN SET & CLOSE Decreases the obstruction force margin setting
FORCE MARGIN SET (then) SET Resets the factory default force margin settings
CLOSE (for 6 secs.) Clears the door limits set positions. Limits then
need to be reset
PLUS(+) (for 6 secs.) Enters pet (pedestrian) position mode
SET (then power on) & hold until all LEDs are off Deletes control parameters excluding transmitter
storage memory
DOOR CODE (then power on) & hold until all LEDs
are off
Deletes all transmitter storage memory
SET & DOOR CODE (the power on) and hold until all
LEDs are off
Deletes all control parameters and transmitter
storage memory.
SET Re-initialises the Opener to re-calculate force
margin