Troubleshooting guide

Owner Installation Instructions GDO-11v1 SecuraLift
®
29
Default Settings & Specifi cations
Factory default settings
Default Step Maximum
Maximum motor run time 60 Secs. - -
Courtesy light time 3 Mins.
10 Sec in battery back
up mode
Obstruction force margin 0.5 Amp 0.1 2 Amp
Technical specifi cations
Power supply 230V - 240V AC 50Hz
Transformer rating 72 VA
Standby power 2.2 Watts
Motor power 90 Watts
Motor type 24V DC permanent magnet
Shuttle travel distance in the C-Rail 3.1m approx (standard)
Maximum shuttle travel distance in the C-Rail 4m (with extended C-Rail)
Maximum door opening: Width:
(With 3160mm Standard track) Height:
Weight:
5500mm (12m
2
)
2150mm
80 kg
Minimum Clearance
(Bottom of C-Rail to highest point of door travel)
25mm
Short term peak force 650N (65kg)
Lift force 400N (40kg)
Nominal force 150N (15kg)
Receiver type Multi-frequency FM Receiver
Receiver code storage capacity 8 x 4 button transmitter codes
Transmitter frequency ~= to 433.92 MHz
Coding type TrioCode™
Number of code combinations Over 4.29 billion random codes
Code generation Non-linear encryption algorithm
Transmitter battery CR 2032
Courtesy light Festoon style lamp 24 volts 15 watts
Controller fuse 10A slow blow
NOTE: Intermittent operations may occur in areas which experience very strong winds. The strong wind
puts extra pressure on the door and tracks which may in turn trigger the safety obstruction detection system
intermittently.
P.E Beams should be fi tted as added safety in case of entrapment.