Specifications

6
OPERATING CONTROLS
P. E. SHUNT. The shunt has to be
removed when connecting a Photo
Electric Beam.
NOTE: P.E. SHUNT must not be
removed otherwise the opener will
not function correctly. Remove
only when a P.E beam is to be
connected.
24V OUTPUT supplies 24V DC
at 30mA to power an external
receiver, or electronic device, etc.
O/S/C INPUT is used for the
connection of a wired switch
(momentary contact). This switch
can then be used to open, stop or
close the door.
LIGHT INPUT is used to control
the courtesy lights either
independently via remote control
or when the door is activated.
LIGHT CODE button (white) is
used for storing or erasing the
transmitter button (code) you wish
to use to switch the openers
courtesy light on and off.
CODING LED (red) light
indicates whether a code is being
stored or when a transmitter button
is pressed.
DOOR CODE button (blue) is
used for storing or erasing the
transmitter button you wish to use
to command the door to open, stop
or close.
STATUS LED (Yellow) indicates
if opener is overloaded or requires
service.
1.
2.
3.
4.
5.
CLOSE drive button (red) is used
only during installation to help set
the close limit position. Pressing
and holding this button will move
the door in the close direction.
Movement stops when the button
is released.
NOTE: The close safety
obstruction detection is
inoperable whenever the Close
Drive button is used to move
door. This button is disabled
after initialisation.
CLOSE LIMIT LED (red) is very
helpful during installation. It
illuminates and flashes when the
door is closing and remains steady
on when the close limit position
has been reached.
AUTO CLOSE TIME button is
used to adjust the auto close time.
While holding in the auto close
button and then pressing the open
button the time is increased. Each
press will increase the time by one
second. Pressing the close button
will decrease the time.
ENGAGE/DISENGAGEMENT
CORD is used to switch the door
into manual mode especially in
case of a power failure. The length
of the string is also adjustable.
EASY ACCESS
TRANSMITTER The
“manual
release”
engage/disengagement
handle has a wireless transmitter.
within its housing If the button is
pressed it will open, stop or close
the garage door.
SET button (orange) is used
during the installation phase
together with the Open and Close
buttons to set the door limit
positions. The Set button is also
used to re-initialise the opener.
6.
7.
8.
9.
10.
O/S/C button (Yellow) is used
after set up to test the Open, Stop
and Close cycles for the opener.
The opener has to be initialised by
the Set button before the O/S/C
button becomes operable.
BATTERY CHARGER INPUT
is used for the connection of a
battery back up kit.
OPEN DRIVE button (green) is
used only during installation to
help set the open limit position.
Pressing and holding this button
will move the door in the open
direction. Movement stops when
the button is released.
NOTE: The open safety
obstruction detection is
inoperable whenever the Close
Drive button is used to move
door. This button is disabled
after initialisation.
OPEN LIMIT LED (green) is
very helpful during installation. It
illuminates and flashes when the
door is opening and remains steady
on when the open limit position
has been reached.
FORCE MARGIN SET is used
to change the obstruction force
margin sensitivity. The obstruction
force pressure is set automatically
by the opener during installation.
The pressure can be adjusted
manually to compensate for
environmental factors such as
wind, etc. that may affect the
operation of the door/opener.
PROG INPUT is used for the
connection of the ATA Universal
Programmer for the purpose of
editing control and receiver
functions.
11.
12.
13.
14.
15.
16.