Installation manual

Owner Installation Instructions GDO-8 Shed Master® 23
Default Settings & Specifi cations
Factory Default Settings
Default Step Maximum
Maximum motor run time 30 seconds - -
Obstruction force margin 8 1 -
Technical Specifi cations
Input: 230v. - 240v AC 50Hz
Controller voltage: 24v. DC
Standby power: 2.8W
Motor power: 100W
Operating temperature +5° to +40°C
Maximum door opening:
1,2
width:
height:
weight:
5500mm
2700mm
100kg
Maximum lifting force: 450N (45kg)
Recommended lifting force: 120N (12kg)
Opener limits travel: 3.25 Turns of door drum wheel
Operating time - intermittent: 4 minutes
Reciever type: UHF 433.92 MHz. am receiver
Receiver code storage capacity: 8 x 4 button TrioCode™ transmitters
Transmitter frequency: 433.92 MHz
Coding type: Code hopping
No. of code combinations: Over 4.29 billion random codes
Code generation: Non-linear encryption algorithm
PTX-5 transmitter battery: CR2032
NOTE:
1. The maximum continuous curtain residential roll up door opening that the GDO-8 Shed Master ® can be
installed on is 5500mm wide by 2700mm high. The door must be well balanced. A person of average strength
should be able to lift up the door manually with very little effort in case of an emergency.
2. Intermittent operations may occur in areas which experience very strong winds. The strong wind puts extra
pressure on the door and tracks which may in turn trigger the safety obstruction detection system intermittently.