Instruction manual

8
GDO-6v3 EasyRoller
®
Owner Installation Instructions
Operating Controls
TERMINAL BLOCK
24V (not fi ltered or regulated) PWR is used to power photo electric beam.
PE (Input) for photo electric beam.
PE (-) is used to power photo electric beam.
GND is used with OSC input or AUX output
O/S/C INPUT is used for the connection of a wired switch (momentary contact). This switch can
then be used to open, stop or close the door. Install the wall switch in a location where the switch
is out of reach of children and the garage door is visible.
AUX (output) can be used to control an alarm system.
LIGHT CODE button (White) is used for storing or erasing the transmitter button (code) you wish to use
to switch the courtesy light on the opener on or off.
CODING LED (Red) light fl ashes when a code is being stored or when a transmitter button is pressed.
DOOR CODE BUTTON (Blue) is used for storing or erasing transmitter buttons for door operation.
DOOR STATUS LED (Yellow)
CLOSE button (Red) is used during installation to help set the close limit position. Pressing and holding
this button will move the door in the close direction. Movement stops when the button is released.
NOTE: The safety obstruction detection is inoperable when the CLOSE button is used to move door.
CLOSE LIMIT LED (Red) the LED is very helpful during installation. It illuminates and fl ashes when the
door is closing and remains steady on when the close limit position has been reached.
AUTO CLOSE TIME button (White) is used to adjust the Auto-Close time. Pressing the open button
whilst pressing the Auto Close button increases length of operation. Each press will increase the time by 5
seconds. Pressing the close button will decrease the time.
FORCE MARGIN SET button. The obstruction force margin is set automatically during installation. The
margin can be adjusted manually using the Force Margin Set button (White). Holding the Force Margin
Set button and pressing OPEN or CLOSE buttons will increase or decrease the amount of force. The Force
Margin Set should only be used if environmental factors (wind, etc.) affect the door’s operation.
OPEN LIMIT LED (Green) the LED is very helpful during installation. It illuminates and fl ashes when the
door is opening and remains steady on when the open limit position has been reached.
OPEN button (Green) is used during installation to help set the open limit position. Pressing and holding
this button will move the door in the open direction, releasing stops the door.
NOTE: The safety obstruction detection is inoperable when the OPEN button is used to move door.
OPERATE button (Yellow) is used during installation to test the open, stop and close cycles for the
opener. The opener has to be initialised by the Reset button to make the O/S/C button operable.
SET button (Yellow) is used during the installation phase together with the Open and Close buttons to set
the door limit positions. The Set button is also used to re-initialize the Opener.
ENGAGE/DISENGAGEMENT CORD enables manual door operation, especially useful during
power failures. At the cord’s end is the
EASY ACCESS TRANSMITTER; a wireless door controller.
01
02
03
04
05
06
07
08
09
10
11
12
14
13