 Auto-Close
Step 15 - Setting Up Auto-Close Mode
IMPORTANT NOTICE: It is compulsory to have PE 
Beams installed when using Auto-Close mode.
Auto-Close mode is a function that automatically closes 
the door a preset time after the PE Beams recognise that 
a vehicle has left the garage.
The Auto-Close timer only starts after the PE Beam’s 
path is broken. If the PE path is not broken, the door will 
remain open until the path is broken. If the opener incurs 
a physical obstruction (i.e. not from the PE Beams) while 
closing the door, it will re-open and not Auto-Close until 
the PE Beam’s path is broken again.
Step 15.1 - Setting Auto-Close Time
Hold down the AUTO CLOSE TIME button (Fig. 31).
While holding in the AUTO CLOSE TIME button, 
press the OPEN button - each press will add one 
second to the Auto-Close delay.
To decrease the delay time follow Step 15.1(a) 
and press the CLOSE button - each press will 
deduct one second from the Auto-Close delay.
Press the OPERATE button or transmitter to open 
the door. When the door is fully opened the 
OPEN LIMIT LED will fl ash to indicate that Auto-
Close mode is operational. 
Break the PE Beam’s path momentarily to 
initialise Auto-Close. When the door reaches the 
fully opened position, the door will pause for the 
set Auto-Close time and then close.