Technical data
7
STOP
PUMP’S OPERATION
FAN’S OPERATION
FIRING-UP MODE
BLOW-THROUGH - INTERNAL TIME
FLUSHING - OPERATING TIME
Description of the regulator’s panel
4.5. Technical data of the regulator EKOSTER 2
1. Temperature range -9°C do +99°C
2. Temperature setting +60°C do +80°C
3. Temperature of the pump’s connecting +65°C or controlled with the thermostat
4. Blowdown regulation
seconds 0-90
break 1-15 minutes
possibility of full blushing
turning of
P-0
5. Hysterezis (the difference turn on- turn off) From 2 up to 9°C
6. Maximum switching power
fan 100 W
pump 100 W
7. Mains supply voltage / Frequency 230 V AC, 50 Hz
8. Maximum power consumption 275 VA
9. Fan’s regulating power in % x 10 (regulation range from 20 - 100%)
10. Outside humidity
≤ 95%
11. Protectionrating IP 40
12. Insulation class
I
4.4. Front panel of EKOSTER 2 regulator