4.2. Regulator system functions (RK 2001)
Boiler’s temperature
setting at 60 up to
80°C
We set the boiler’s temperature with a knob (6). Current temperature is displayed on the
screen (2).
Boiler’s overheating
signalling
The indicator (4) tells about boiler’s temperature excees to 90°C. In the case the fan switches
off.
Lack of fuel signal
-
lisationl
If in 30 minutes temperature doesn’t reach 60°C, the indicator (8) and the fan will turn on.
Wrong burning up
signallization
If the boiler doesn’t reach 60°C during burning up (up to 2 hours) , the indicator (8) will light
up and the fan will turn off.
NOTICE
! In the case wood can remain in the boiler.
Fans operating
controlling
Regulator modulates fans operating and it upholds its depending on boilers temperature.
Pumps operating
controlling
If pump is connected to regulator:
while burning up pump is turned off till the time when boiler reaches 65°C
when here is more than 65°C the pump still works till the time of temperature decreasing
(60°C) then it stops. Next time it activates when temperature reaches over 65°C
Room temperature
controlling
Boiler comes together with the sensor which can be placed in the room. Regulator control
with the boiler’s work in such a way that it keeps temperature needed in the room.
Cooperation with
room thermostat
Boiler can cooperate with any room thermostat* which should be connected instead of a
room thermostat
* NOTICE! If there is a room sensor or room thermostat connected to the boiler then
the boiler will stay in watching stage and then its continuous temperature is 60 - 65°C. If
temperature decreases under the needed one , boiler starts working again.
Scavenging Regulator can ush of the loading chamber in order to get rid of gathered wood gas. The
function activates while boiler’s lay over after reaching the temperature congurated. When
the boiler reaches the temperature 10% higher from the one setted on regulator,ushing
function will turn off till the time of the temperature’s decreasing to the level underneath.
Flushing time is 5 seconds , timing interval between nextushes depends on the regulator
settings and it is 1 up to 9 minutes.
NOTICE! Technical service should deal with ushing regulation.
4.3. Pump’s and room sensor’s connecting
There is a connecting board at the back side of regulator where pump and room sensor can be
connected. The access for connecting board is possible only after the regulator’s disconnecting
and safety lid unscrewing. At the back panel there are some graphic markers and descriptions
featuring right elements’ connection placement.