Technical data
5
3.1. Diagram of chimney choice according to DIN 4705 norm
4. Regulator’s description
Since the 30.06.2006 wood boilers were equipped with RK 2001 regulator. In 01.07.2006 new
ones were brought out - EKOSTER 2. Main functions of both regulators are similar, but there is a
difference in parameters’ modication ( EKOSTER 2 ).
4.1. Technical data of RK 2001 regulator
Power 230V +/- 10%
Rate supply voltage (with no fan) < 4VA
Temperature measurement range 0 do 99 +/- 1 °C
Temperature measurement sensors
KTY 81 210
Temperature regulation range 60 - 80 °C
Electrical protection (fuse)
1A/220V
Boiler’s power [kW]
Internal diameter of chim-
ney ue (mm)
Thrust needed [Pa]
Chimney height [m]
1. Power cut-out
2. Boiler’s temperature display
3. Burning up indicator
4. Overheating indicator
5. Room thermostat indicator
6. Boiler’s thermostat knob
7.
Pump’s operating indicator (the green one)
8. Fuel shortage indicator (the green one)
9. Room thermostat knob (the green one)
10. Boiler’s temperature setting test
Rys. 2 Front panel of the RK 2001 regulator
1 2 3 4 5 6
9 8 7 10