Technical data

4
3. Installation
Wood boilers are to be installed according to the present norms and rules. The requirements of
norm PN 87/B 02411 according building of solid fuel boiler room and the norm PN-91/B-02413 ac-
cording open system boilers’ producing should be taken into account.
Eko-Vimar Orlański company prescribes using chimney inputs which preserve against the
chimney permeating. The company doesn’t take responsibility in case of faults resulting from not
using chimney inputs.
1. Chimney ue should correspond to the parameters of „DIAGRAM OF CHIMNEY CHOSING
ACCORDING TO THE DIN 4705 NORM”.
2. Boiler room should be large enough to enable boiler’s cleaning (>2,2 m).
3. The distance between the boiler and the partitions should enable right access for all of the
boiler’s parts - it shouldn’t be less than - look at “Orlan boiler’s placing”.
Orlan boiler’s placing
4. There shouldn’t be any cables nor electric installations which aren’t for boiler’s room using.
Before smoke outlet’s connecting to the chimney ue, there should be a chimney sweeps ap-
proval.
According to the PN-EN 303-5 norm accumulation tank should be assembled together with wood
boiler - its capacity is listed in reference to the . 4.2.5. point in the norm