Technical data

18
7.4. Leakproof securing
Leakproof of the boiler is very important especially leakproof of the door, the exchanger and
chimney ap. Leakproof causes the fumes’ coming out of the boiler and most of all it can cause
uncontrolled burning which may cause boiler’s overheating. To ensure the exchangers door leak-
proof the insulation rope should be sealed with a graphite oil or some other machine oil at least
once a week. It soften the rope and causes its tight adjoining to the boiler.
After some time of boiler’s operating (1 season for example) the door rope could get atted. To
assure right rope’s adjoining to the boiler’s door, door’s setting regulation is provided (regulation
on the hinge).
Hinge door setting:
a) take the door off
b) Loosen the cap
c) turn the hinge 360°
d) turn a tap tight to block hinge’s
regulating screw.
NOTICE!
Upper and down hinge should be
regulated in the same time.
Rys. 8 Cleaning elements
- only for STANDARD version
NOTICE!
Chimney ue’s leakproof should be controlled and if such a need occurs - it should be
cleaned out. All of the threaded elements before their unscrewing should be lubricat-
ed with grease. Door and hinges should be lubricated temporarily as well.
blocking nut