Technical data
18
7.4. Leakproof securing
Leakproof of the boiler is very important especially leakproof of the door, the exchanger and
chimney ap. Leakproof causes the fumes’ coming out of the boiler and most of all it can cause
uncontrolled burning which may cause boiler’s overheating. To ensure the exchanger’s door leak-
proof the insulation rope should be sealed with a graphite oil or some other machine oil at least
once a week. It soften the rope and causes its tight adjoining to the boiler.
After some time of boiler’s operating (1 season for example) the door rope could get atted. To
assure right rope’s adjoining to the boiler’s door, door’s setting regulation is provided (regulation
on the hinge).
Hinge door setting:
a) take the door off
b) Loosen the cap
c) turn the hinge 360°
d) turn a tap tight to block hinge’s
regulating screw.
NOTICE!
Upper and down hinge should be
regulated in the same time.
Rys. 8 Cleaning elements
- only for STANDARD version
NOTICE!
Chimney ue’s leakproof should be controlled and if such a need occurs - it should be
cleaned out. All of the threaded elements before their unscrewing should be lubricat-
ed with grease. Door and hinges should be lubricated temporarily as well.
blocking nut