Determining Your System Mounting Hole Layout
Based on your actual axis module combination, use the following
illustration and table to modify your subpanel using the dimensions
that correspond to that specific combination.
Figure 1.3
1394 Mounting Hole Layout
Note: When mounting axis module combinations, you must mount the 1394x-AM50, -AM75, -AM50-IH, and -AM75-
IH closest to the system module and ahead of the 1394x-AM03, -AM04, and -AM07 axis modules.
Axis Module
Combination
Type of Axis Module Number of Axes Cutout Needed?
A
1394x-AM50, or -AM75, and
1394C-AM50-IH, or -AM75-IH
0no
1394x-AM03, AM04, or AM07 up to 4 no
B
1394x-AM50, or -AM75, and
1394C-AM50-IH, or -AM75-IH
1
yes (1394x-AM50 or -AM75)
no (1394C-AM50-IH or -AM75-IH)
1394x-AM03, AM04, or AM07 up to 3 no
C
1394x-AM50, or -AM75, and
1394C-AM50-IH, or -AM75-IH
2
yes (1394x-AM50 or -AM75)
no (1394C-AM50-IH or -AM75-IH)
1394x-AM03, AM04, or AM07 up to 2 no
D
1394x-AM50, or -AM75, and
1394C-AM50-IH, or -AM75-IH
3
yes (1394x-AM50 or -AM75)
no (1394C-AM50-IH or -AM75-IH)
1394x-AM03, AM04, or AM07 up to 1 no
E
1394x-AM50, or -AM75, and
1394C-AM50-IH, or -AM75-IH
4
yes (1394x-AM50 or -AM75)
no (1394C-AM50-IH or -AM75-IH)
50
(1.97)
0
(0.00)
62.5
(2.46)
50
(1.97)
125
(4.92)
100
(3.94)
137.5
(5.41)
175
(6.89)
200
(7.87)
212.5
(8.37)
225
(8.86)
250
(9.84)
275
(10.83)
287.5
(11.32)
B
C
D
E
B
B
B
C
D
E
A
C
C
D
E
DE
19.5
(0.768)
33.5 TYP
(1.32)
67 TYP
(2.64)
8 TYP
(0.32)
M6 tapped hole or
1/4-20 UNC - 2B
385
(15.16)
348
(13.70)
AAA
150
(5.91)
System module
mounting holes
Heatsink
cutout for the
AM50/75
module
only
Heatsink
cutout for the
AM50/75
module
only
Heatsink
cutout for the
AM50/75
module
only
Heatsink
cutout for the
AM50/75
module
only
System
outline
Dimensions are in millimeters and (inches)