Installation guide
16
©
2003
Directed Electronics, Inc.
The dealer default settings only affect the settings listed above. The remaining features control
outputs of the system that must be programmed to meet the needs of the installation. Once the
vehicle is delivered to the end user, two Code Hopping
®
transmitters should be taught to the system.
The system will then operate according to how the operating settings have been preset. It is also
possible to reprogram the operating settings using a standard Code Hopping
®
transmitter if
necessary.
When a Code Hopping
®
transmitter is taught to the system, the master dealer remote is automati-
cally erased from memory.
Troubleshooting
Starter kill does not work:
➤➤
Is the correct starter wire being interrupted? If the car starts when the starter kill relay is
completely disconnected, the wrong starter wire has been cut and interrupted.
➤➤
Is the yellow wire connected to “true” ignition? Make sure this wire is connected to a
wire that has power in the run and start positions.
The Valet
®
switch does not work.
➤➤
Is it plugged into the correct socket? See
Plug-In LED and Valet
®
/Program Switch
section. Is the H1/9 YELLOW wire properly connected? See
Primary Harness (H1) Wire
Connection Guide
section of this guide.
Status LED does not work.
➤➤
Is the LED plugged into the small white port on the side of the control unit? See
Plug-In LED
and Valet
®
/Program Switch
section.
Door locks operate backwards.
➤➤
This unit has easily-reversed lock/unlock outputs. Recheck
Harness 2, (+/-) Door Lock
Outputs
section to see if you have reversed these.
The horn honks when the unit enters panic mode, but the confirmation
honks do not work when locking and unlocking.
➤➤
Are the confirmation honks turned on in programming? See
Operating Settings Learn
Routine
and
Feature Descriptions
sections.
I can get into programming and change the feature settings, but when I
use the remote the settings seem to change.
➤➤
Are you using a binary, master dealer remote? Remember, you can program the settings using a
master dealer remote. However, the unit will follow the dealer default settings when using a
binary remote to operate the system.