Specifications
CNC-210A Series Technical Manual
5
έᚊཝҋજ̼ѣࢨ̳Φ
TAILY AUTOMATION CO.,LTD.
4. INSTALLATION AND WIRING
The controllers should be operated in an environment that is protected from moisture,
corrosive gases, oil mist, and free from airborne dust, metallic particles, and magnetic noise.
Normally operate under 10
℃
~40
℃
environment. Do not block the intake/exhaust ports of the
controller. Otherwise, a fault may occur.
Make sure that the power source supplies the correct voltage and is capable of supplying the
required current to the controllers.
Do not connect or disconnect wires and connectors while power is applied to the controller.
Make sure that the machine and controllers are properly grounded.
Make sure that the leads and connectors are connected correctly.
4.1. I/O signal Interfaces description
Digit input interfaces
:
Give a signal with a relay, switch or open collector transistor.
4.7K
2.2K
+24V
COM
IN PUT
+24V
+24V
+
OUT
SENSOR
CNC-210AS/AE
4.7K
2.2K
COM
IN PUT
+24V
+24V
SWITCH
CNC-210AS/AE
IP1~IP6,PHA,PHB,PHC,HOME START,STOP,RESET
SWITCH
Digit output interfaces
:
A lamp, relay or photo coupler can be driven.
2.2K
+24V
OUT PUT
+24V
LOAD
CNC-210AS/AE
2.2K
+24V
OUT PUT
+24V
LAMP
CNC-210AS/AE
22R
MAX: 24V 0.1A
MAX: 24V 0.1A
OP1~OP4
LAMP1,LAMP2,LAMP3
Motor control signal interfaces
:
(for CNC-210AE only)
CW/RUN
CCW/DIR
CNC-210AE only
MOTOR DRIVER
PUS
DIR
+5V
+5V
330R
330R
V+
PUS
DIR
CNC-210AE only
MOTOR DRIVER
PUS,DIR
V_OUT,CW,CCW,H/L
H/L
V-OUT
(DC 0~10V)
2.2K
VIN
HI/LOW
CW/RUN
CCW/DIR
COM COM
+24V
COM