Specifications
CNC-210A Series Technical Manual
14
έᚊཝҋજ̼ѣࢨ̳Φ
TAILY AUTOMATION CO.,LTD.
8. MAINTAIN AND TROUBLESHOOTING
8.1. Periodically maintain
Please periodically clean up the controller inner accumulate dust and departs.
Please periodically check the wire connection between controller and machine if have loose or
bad contact.
The following parts must be maintained or changed periodically as list below. If any part is
found faulty, it must be changed immediately even when it has not yet reached the end of its
life, which depends on the operating method and environmental condition.
For parts replacement, please contact your sales representative.
NO Parts name Life guideline
1
Winding spindles Turns counter
CNTB-03B/03C
2 years
2
Guiding traverses
HOME SENSOR
2 years
3 COOLING FAN
(DC 12V 6cm)
10,000 hours
4
RELAY
(on the 210A-DVR driver board, it used to switching the
winding direction)
100,000 times
5
Carbon
BRUSH
of the DC motor
1 year
8.2. Error message
When a fault occurs during operation, the DATA DISPLAY shows error massage, stop winding
and then RESET go back to the READY mode.
Err-0
:
The parameters or data in memory are fault.
Err-1
:
The
『
SHIFT
』
value sets exceed the Travel Limit.
Err-2
:
During winding, the guiding traverse to exceed the Travel Limit.
Err-3
:
During winding, the guiding traverses
reach to the Home sensor.
Err-5
:
RS-485 communication error.
Err-p
:
Password error, key in 4 digits password before edit.
8.3. To abort seeks the original position
At boot and reset procedures, if because of unknown reason however engender the winding
shaft and guiding traverse can't find out the original position and make the controller can't get into
ready mode, can press key to abort seeks the original position, make controller get into ready
mode.
8.4. Troubleshooting
This section provides information to guide the user in understanding different fault condition and
their general troubleshooting procedures, and with their possible solutions.
Do not connect or disconnect wires and connectors while power is applied to the controller.
Make sure that the leads and connectors are connected correctly, before doing the
troubleshooting procedures.
Do not remove welded parts on the PC board without appropriate tools.