Installation Manual
Title: Installation Specifications and User Manual, Radar
Sensors
Doc. No. E567781
INSTALLATION SPECIFICATION Rev. 001, Page 9 of 14
5.0 SPECIFICATIONS
5.3 Installation Specifications For Individual Sensors
(cont’d)
5.3.6 Environmental Conditions
The following lists the environmental conditions the sensor is designed
to operate in. The location and mounting of the sensor must not create
conditions that exceed the following:
1. Temperature extremes and applicable tests according to SAE
J1211 Table 1, Zone 2.1
2. Operational Integrity according to SAE J1812, Range 1
3. Functional Classification according to SAE J1812, Class B
4. Generic Environmental Requirements SAE J1879
Examples:
Operating Temperature
: -40° to +85°C
Assumes non-moving air, sensor
backside surface exposed to free
air.
Max. Storage Temp
: +105 °C
5. Temperature tests SAE J1211 4.1, 5.9 IEC68-2-1 Aa,
Ab, Ad, IEC68-2-2, Ba, Bb, Bd,
IEC68-2-33, IEC68-2-14, SAE
J1879 4.1, IEC68-2-18 Rb3,
IEC68-2-14 Nc, IEC68-2-5
6. Humidity test Per IEC68-2-56 Cb, Db IEC68-2-
30, IEC 68-2-10, IEC68-2-38, SAE
J1211 4.2, 5.9,
7. Mechanical Shock Per IEC 68-2-27 Ea & Eb & IEC
68-2-29
8. Vibration over Temp. Per IEC 68-2-64Fh & IEC 668-2-
14Nb, IEC68-2-50, IEC68-2-51
9. Free Fall Per IEC 68-2-32 Ed, Version 1
10. Constant Acceleration Per IEC 68-2-7
11. Resonance frequency Per IEC 68-2-6 Fc, SAE J1211
4.7, 5.9
12. Salt Spray Per IEC68-2-11 Ka , IEC68-2-52
13. Water Immersion/Protection Per DIN 40050-9 IP6K9K
14. Dust Protection Per DIN 40050-9 IP6K9K &
IEC529, 13.4
15. Fluid Compatibility according to installation area