User Manual

File Name: 24 GHz SQ_Technical Description_Installation Guide
Date: 31. July 2013
Autoliv Document, DUPLICATION or DISCLOSURE PROHIBITED without prior written consent
8 (9)
4 Vehicle Integration
Autoliv has experienced with body mounted and fascia mounted attachment. Preferably, the sensor slides in a
plastic bracket attached onto the fascia as represented below:
The packaging guidelines have proven to be effective in use at several OEM’s in series production using AUTOLIV
radars. Highlights of the guidelines:
Keep out zone in front of sensor
No metal parts (screws, license plates, clips, etc), impact absorbing foam, fascia creases) inside +/- 65 deg
azimuth, +/- 30 deg elevation
Sensor spacing from fascia 5mm to 20 mm