5.0 SPECIFICATIONS
5.2 C6 Sensor (cont’d)
5.2.3 Keep-out zone, Angle Elevation
Within the elevation keep out zone there must not be metal parts like screws,
mounting brackets, license plate etc. The impact reducing foam material, clips or
fascia laminations has to be avoided in that area.
Within the keep out zone of the antennas there must be no vertical character
lines present in the fascia (see 5.3.5). Mounting bracket material shall not enter
the keep out zone. Bracket retention features which interface with the surface of
the sensor radome shall not enter the keep out zone noted in Section 5.2.5
The elevation material keep out zone in elevation is ±30°. This angle is
established 7mm from the edge of the sensor.
Figure 3