Installation Manual
Title:
Installation Specifications and User Manual, Radar
Sensor, C6
Doc. No. E805913
INSTALLATION SPECIFICATION Rev. 003, Page 5 of 12
5.0 SPECIFICATIONS
5.2 C6 Sensor (cont’d)
5.2.2 Keep-Out Zone / Azimuth Angle Measurement Range
Figure 2 displays the keep out area of the C6 sensor.
Within the detection area of the antennas there must not be objects like screws,
mounting brackets, license plates etc. The impact reducing foam material, clips
or fascia laminations has to be avoided in that area.
Within the keep out zone of the antennas there must be no vertical character
lines present in the fascia (see 5.3.5). Mounting bracket material shall not enter
the keep out zone. Bracket retention features which interface with the surface of
the sensor radome shall not enter the keep out zone noted in Section 5.2.5
The keep out zone in the azimuth direction is ±65°. The angle is established
7mm from the edge of the sensor.
Figure 2