2011
Table Of Contents
- Contents
- Welcome to Autodesk Navisworks Simulate 2011
- What Is New in This Release?
- How to Get Assistance
- Finding Information Using the InfoCenter
- Get More Help
- Learn the Product
- View the Product Readme
- Join the Customer Involvement Program
- Installation
- Quick Start to Stand-Alone Installation
- Prepare for Installation
- Install and Run Autodesk Navisworks Simulate 2011
- Move to Autodesk Navisworks from a Previous Release
- Install Autodesk Navisworks for Multiple Users
- Quick Start to Network Administration and Deployment
- Set Up a Deployment
- Installation Troubleshooting
- General Installation Issues
- How can I check my graphics card driver to see if it needs to be updated?
- When performing a Typical installation, what gets installed?
- Why should I specify the Project Folder and Site Folder?
- How do I share the Autodesk Navisworks settings on a site and project basis?
- Where are my product manuals?
- How do I register and activate Autodesk Navisworks?
- Deployment Issues
- Licensing Issues
- Networking Issues
- Uninstall and Maintenance Issues
- When adding or removing features, how can I tell what features get installed by default?
- Is it possible to change the installation folder when adding or removing features?
- When should I reinstall the product instead of a repair?
- Do I need my original DVD to reinstall my software?
- When I uninstall my software, what files are left on my system?
- General Installation Issues
- Quick Start to Stand-Alone Installation
- Quick Start
- Start and Quit Autodesk Navisworks
- Automatically Save and Recover Navisworks Files
- Command Line Options
- The User Interface
- Navigation with the Wheel Button
- Autodesk Navisworks Options
- Location Options
- Display Units
- Profiles
- Search Directories
- Gizmos
- Get a Whole-Project View
- Work with Files
- Native File Formats
- Compatible CAD Applications
- Use File Readers
- 3DS File Reader
- ASCII Laser Scan File Reader
- Bentley AutoPLANT File Reader
- CIS/2 File Reader
- DWG/DXF File Reader
- DWF File Reader
- DGN File Reader
- Faro Scan File Reader
- FBX File Reader
- IFC File Reader
- IGES File Reader
- Inventor File Reader
- JTOpen File Reader
- Leica Scan File Reader
- MAN File Reader
- Parasolid File Reader
- PDS File Reader
- Riegl Scan File Reader
- RVM File Reader
- SAT File Reader
- SketchUp SKP File Reader
- STEP File Reader
- STL File Reader
- VRML File Reader
- Z+F Scan File Reader
- Use File Exporters
- Manage Files
- View Scene Statistics
- Explore Your Model
- Control Model Appearance and Render Quality
- Review Your Model
- Use Viewpoints and Sectioning Modes
- Record and Play Animations
- Work Within a Team
- Share Data
- Work with Files
- Animate Objects
- Create Photorealistic Visualizations
- Simulate Construction Scheduling
- Autodesk Navisworks Reference
- Animation Export Dialog Box
- Background Settings Dialog Box
- Collision Dialog Box
- Convert Object Properties Dialog Box
- Culling Options Dialog Box
- Customize Dialog Box
- Default Collision Dialog Box
- Edit Key Frame Dialog Box
- Edit Link Dialog Box
- Edit Viewpoint Dialog Box
- Export Rendered Image Dialog Box
- File Options Dialog Box
- File Units and Transform Dialog Box
- Image Export Dialog Box
- InfoCenter Settings Dialog Box
- New Link Dialog Box
- Options Editor Dialog Box
- Publish Dialog Box
- Piranesi EPix Dialog Box
- QTVR Object Movie Settings Dialog Box
- Section Plane Settings Dialog Box
- Glossary
- Index
ASCII Laser Page
Use this page to adjust the options for the ASCII laser scan file reader.
Sample Rate Specifies the frequency of points extracted from the input file.
Increasing the sample rate, reduces the number of points extracted. This has the effect of reducing the image
resolution, but increasing the speed with which the file is loaded.
Use Point Intensity Values Select the check box to extract intensity values from the input file.
When this check box is clear, the file reader ignores intensity values.
Use Point Color Values Select the check box to extract color values from the input file.
When this check box is clear, the file reader ignores color values.
See also:
■ “
ASCII Laser Scan File Reader” on page 116
CIS/2 Page
Use this page to adjust the options for the CIS/2 file reader.
Convert Features Indicates whether features are converted.
NOTE Converting a large number of features may have a negative impact on the loading performance.
Convert Unknown Section into Rectangle Select this check box to convert unknown sections profiles into
rectangles with estimated parameters, but the scale may not be appropriate.
When this check box is clear, the file reader ignores unknown sections profiles.
Faceting Factor Enter the required value to control the level of faceting that takes place.
The faceting factor must be greater or equal to 0, where 0 results in the faceting factor being turned off. The
default value is 1. To get twice the number of facets, double this value. To get half as many facets, halve this
value. Larger faceting factors result in more polygons to a model and larger Autodesk Navisworks files.
Max Facet Deviation This setting controls the greatest distance between the edge of a facet and the actual
geometry. If this distance is greater than the Max Facet Deviation value, Autodesk Navisworks adds more facets.
If the Max Facet Deviation is set to 0, then this function is ignored.
DGN Page
Use this page to adjust the options for the 3D DGN and PROP file reader.
Faceting Factor Enter the required value to control the level of faceting that takes place.
The faceting factor must be greater or equal to 0, where 0 results in the faceting factor being turned off. The
default value is 1. To get twice the number of facets, double this value. To get half as many facets, halve this
value. Larger faceting factors result in more polygons to a model and larger Autodesk Navisworks files.
Max Facet Deviation This setting controls the greatest distance between the edge of a facet and the actual
geometry.
If this distance is greater than the Max Facet Deviation value, Autodesk Navisworks adds more facets.
If the Max Facet Deviation is set to 0, then this function is ignored.
Convert Hidden Items Select this check box to convert hidden entities in DGN files. They are automatically
marked as hidden by Autodesk Navisworks.
When this check box is clear, the file reader ignores hidden items.
Show Hidden Items Select this check box, if you want to display all entities in converted DGN files, irrespective
of whether they are hidden or not.
NOTE To use this option, you must select the Convert Hidden Items check box.
454 | Chapter 16 Autodesk Navisworks Reference