2011
Table Of Contents
- Contents
- Welcome to Autodesk Navisworks Simulate 2011
- What Is New in This Release?
- How to Get Assistance
- Finding Information Using the InfoCenter
- Get More Help
- Learn the Product
- View the Product Readme
- Join the Customer Involvement Program
- Installation
- Quick Start to Stand-Alone Installation
- Prepare for Installation
- Install and Run Autodesk Navisworks Simulate 2011
- Move to Autodesk Navisworks from a Previous Release
- Install Autodesk Navisworks for Multiple Users
- Quick Start to Network Administration and Deployment
- Set Up a Deployment
- Installation Troubleshooting
- General Installation Issues
- How can I check my graphics card driver to see if it needs to be updated?
- When performing a Typical installation, what gets installed?
- Why should I specify the Project Folder and Site Folder?
- How do I share the Autodesk Navisworks settings on a site and project basis?
- Where are my product manuals?
- How do I register and activate Autodesk Navisworks?
- Deployment Issues
- Licensing Issues
- Networking Issues
- Uninstall and Maintenance Issues
- When adding or removing features, how can I tell what features get installed by default?
- Is it possible to change the installation folder when adding or removing features?
- When should I reinstall the product instead of a repair?
- Do I need my original DVD to reinstall my software?
- When I uninstall my software, what files are left on my system?
- General Installation Issues
- Quick Start to Stand-Alone Installation
- Quick Start
- Start and Quit Autodesk Navisworks
- Automatically Save and Recover Navisworks Files
- Command Line Options
- The User Interface
- Navigation with the Wheel Button
- Autodesk Navisworks Options
- Location Options
- Display Units
- Profiles
- Search Directories
- Gizmos
- Get a Whole-Project View
- Work with Files
- Native File Formats
- Compatible CAD Applications
- Use File Readers
- 3DS File Reader
- ASCII Laser Scan File Reader
- Bentley AutoPLANT File Reader
- CIS/2 File Reader
- DWG/DXF File Reader
- DWF File Reader
- DGN File Reader
- Faro Scan File Reader
- FBX File Reader
- IFC File Reader
- IGES File Reader
- Inventor File Reader
- JTOpen File Reader
- Leica Scan File Reader
- MAN File Reader
- Parasolid File Reader
- PDS File Reader
- Riegl Scan File Reader
- RVM File Reader
- SAT File Reader
- SketchUp SKP File Reader
- STEP File Reader
- STL File Reader
- VRML File Reader
- Z+F Scan File Reader
- Use File Exporters
- Manage Files
- View Scene Statistics
- Explore Your Model
- Control Model Appearance and Render Quality
- Review Your Model
- Use Viewpoints and Sectioning Modes
- Record and Play Animations
- Work Within a Team
- Share Data
- Work with Files
- Animate Objects
- Create Photorealistic Visualizations
- Simulate Construction Scheduling
- Autodesk Navisworks Reference
- Animation Export Dialog Box
- Background Settings Dialog Box
- Collision Dialog Box
- Convert Object Properties Dialog Box
- Culling Options Dialog Box
- Customize Dialog Box
- Default Collision Dialog Box
- Edit Key Frame Dialog Box
- Edit Link Dialog Box
- Edit Viewpoint Dialog Box
- Export Rendered Image Dialog Box
- File Options Dialog Box
- File Units and Transform Dialog Box
- Image Export Dialog Box
- InfoCenter Settings Dialog Box
- New Link Dialog Box
- Options Editor Dialog Box
- Publish Dialog Box
- Piranesi EPix Dialog Box
- QTVR Object Movie Settings Dialog Box
- Section Plane Settings Dialog Box
- Glossary
- Index
To add a task type definition
1 If the TimeLiner window is not already open, click Home tab ➤ Tools panel ➤ TimeLiner
.
2 Click the Configure tab, right-click in the Task Types area, and click Add on the shortcut menu.
3 A new task type is added to the bottom of the list; it will be highlighted, enabling you to enter a new name
for it.
4 Use the drop-down buttons to the right of each of the Appearance field to assign the desired object behavior.
You can customize the following properties:
■ Start Appearance - how the items will look at the start of the task, for example Transparent Green.
■ End Appearance - how the items will look when the task is completed, for example Hidden.
■ Early Appearance - how the items will look if the task is started before the planned time, for example
Transparent Yellow.
■ Late Appearance - how the items will look if the task is started after the planned time, for example
Transparent Red.
■ Simulation Start Appearance - how the items should be displayed at the start of a simulation.
NOTE As a minimum, you need to define the Simulation Start Appearance; this assigns a unique start appearance
to your task type. If you do not configure this field, the start appearance set in Default Simulation Start Appearance
will be used instead.
To delete a task type definition
1 If the TimeLiner window is not already open, click Home tab ➤ Tools panel ➤ TimeLiner
.
2 Click the Configure tab, right-click the task type definition, and click Delete on the shortcut menu.
To add an appearance definition
1 If the TimeLiner window is not already open, click Home tab ➤ Tools panel ➤ TimeLiner
.
2 Click the Configure tab, right-click in the Appearance Definition area, and click Add on the shortcut menu.
3 A new appearance definition is added to the bottom of the list; it will be highlighted, enabling you to enter
a new name for it.
4 In the Transparency % field, use the Up and Down controls to set the transparency level, between 0% and
100% (where 0% is opaque and 100% is fully transparent).
5 In the Color field, click on the color to open the color selector. From here, either select one of the basic
colors available, or click Define Custom Colors to define your own color choice.
To delete an appearance definition
1 If the TimeLiner window is not already open, click Home tab ➤ Tools panel ➤ TimeLiner
.
2 Click the Configure tab, right-click the appearance definition, and click Delete on the shortcut menu.
To change the default simulation start appearance
1 If the TimeLiner window is not already open, click Home tab ➤ Tools panel ➤ TimeLiner
, and click
the Configure tab.
Configure Simulations | 419